Optimising slit-lamp biomicroscope fluorescein imaging filters

AIM: Fluorescein dye plays a pivotal role in ophthalmic care as a diagnostic agent due to its fluorescent properties when exposed to blue light. This study examined the spectral profile of blue and yellow filters within commercial slit lamps with a view to determining whether these are optimal. METHODS: The spectral transmission of the white light, blue filtered light(s) and inbuilt yellow filters (where available) of 16 models of slit lamp biomicroscope from 11 different manufacturers were measured with a spectrophotometer. To confirm the peak wavelength required to excite sodium fluorescein dye, the intensity of fluorescence was measured in vitro on exposure to blue light of narrow wavelength bands between 400 and 490 nm. Finally, the effect of altering the blue light, from a Cobalt filter profile (broad ranged with a peak around 450 nm) to one centred at approximately 490 nm, was demonstrated on-eye at 1-min intervals post-fluorescein dye instillation. RESULTS: Most slit lamp blue lights had a similar spectral profile to Cobalt blue, with a peak wavelength of between 443 and 463 nm. The spectral width of the blue light band at 50% of its height was significantly greater with a tungsten (63 to 80 nm) than a LED source (20 to 40 nm; p < 0.001). Yellow filters had a 50% cut-off of 512.3 to 524.5 (with a 16.0 to 33.3 nm range), higher than the optimal ∼505 nm. Optimising blue and yellow filters improved fluorescein visibility by 1.8 ± 0.3× (p < 0.05). CONCLUSION: Despite the suboptimal transmission of Cobalt blue filters for exciting fluorescein molecules, their use prevails in the majority of slit lamps, and the yellow filters lack a sharp spectral cut-off. Adopting new "fluoro-" enhanced slit-lamp illumination filters would address shortcomings of existing filters.

Authors

Institutions

Publication Details

Journal
Contact Lens and Anterior Eye
Published
2026-05-29
DOI
https://doi.org/10.1016/j.clae.2026.102669
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimising slit-lamp biomicroscope fluorescein imaging filters

Jennifer P. Craig, James S. Wolffsohn, Patrick W.K. Ting, Olivia A. Hunt
Contact Lens and Anterior Eye
Advanced Fluorescence Microscopy Techniques
article

Optimising slit-lamp biomicroscope fluorescein imaging filters

Jennifer P. Craig, James S. Wolffsohn, Patrick W.K. Ting, Olivia A. Hunt
article en

Abstract

AIM: Fluorescein dye plays a pivotal role in ophthalmic care as a diagnostic agent due to its fluorescent properties when exposed to blue light. This study examined the spectral profile of blue and yellow filters within commercial slit lamps with a view to determining whether these are optimal. METHODS: The spectral transmission of the white light, blue filtered light(s) and inbuilt yellow filters (where available) of 16 models of slit lamp biomicroscope from 11 different manufacturers were measured with a spectrophotometer. To confirm the peak wavelength required to excite sodium fluorescein dye, the intensity of fluorescence was measured in vitro on exposure to blue light of narrow wavelength bands between 400 and 490 nm. Finally, the effect of altering the blue light, from a Cobalt filter profile (broad ranged with a peak around 450 nm) to one centred at approximately 490 nm, was demonstrated on-eye at 1-min intervals post-fluorescein dye instillation. RESULTS: Most slit lamp blue lights had a similar spectral profile to Cobalt blue, with a peak wavelength of between 443 and 463 nm. The spectral width of the blue light band at 50% of its height was significantly greater with a tungsten (63 to 80 nm) than a LED source (20 to 40 nm; p < 0.001). Yellow filters had a 50% cut-off of 512.3 to 524.5 (with a 16.0 to 33.3 nm range), higher than the optimal ∼505 nm. Optimising blue and yellow filters improved fluorescein visibility by 1.8 ± 0.3× (p < 0.05). CONCLUSION: Despite the suboptimal transmission of Cobalt blue filters for exciting fluorescein molecules, their use prevails in the majority of slit lamps, and the yellow filters lack a sharp spectral cut-off. Adopting new "fluoro-" enhanced slit-lamp illumination filters would address shortcomings of existing filters.

Contact Lens and Anterior EyeVol. 49(4)
University of Auckland (NZ), Aston University (GB)
Affordable and clean energy
Openalex Percentile: Top 7%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.