On the Use of Clarke Transformation for the Transient Analysis of Asymmetrical Faults in Three-Phase Power Systems

This work provides a theoretical/methodological contribution to the transient analysis of asymmetrical faults in three-phase systems. Transient analysis of three-phase systems is usually performed by resorting either to the instantaneous Symmetrical Component Transformation (SCT) or to numerical methods. In this paper, an analytical methodology based on the time-domain Clarke transformation is presented for the transient analysis of the most common asymmetrical faults. For each kind of asymmetrical fault, a specific circuit coupling between the Clarke αβ0 circuits is derived. Two main advantages are obtained over the SCT approach. First, the Clarke circuits involve real-valued voltages/currents, instead of complex variables as with the SCT. Second, the Clarke circuits αβ0 are not all coupled to each other. Therefore, the dynamic order of the Clarke equivalent circuits is lower than that of the SCT circuits. This property can be of interest in both the derivation of analytical and numerical solutions. A simple radial system is used to exemplify the proposed methodology.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-05-27
DOI
https://doi.org/10.3390/en19112580
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Use of Clarke Transformation for the Transient Analysis of Asymmetrical Faults in Three-Phase Power Systems

Diego Bellan
Energies
HVDC Systems and Fault Protection
article

On the Use of Clarke Transformation for the Transient Analysis of Asymmetrical Faults in Three-Phase Power Systems

Diego Bellan
article en

Abstract

This work provides a theoretical/methodological contribution to the transient analysis of asymmetrical faults in three-phase systems. Transient analysis of three-phase systems is usually performed by resorting either to the instantaneous Symmetrical Component Transformation (SCT) or to numerical methods. In this paper, an analytical methodology based on the time-domain Clarke transformation is presented for the transient analysis of the most common asymmetrical faults. For each kind of asymmetrical fault, a specific circuit coupling between the Clarke αβ0 circuits is derived. Two main advantages are obtained over the SCT approach. First, the Clarke circuits involve real-valued voltages/currents, instead of complex variables as with the SCT. Second, the Clarke circuits αβ0 are not all coupled to each other. Therefore, the dynamic order of the Clarke equivalent circuits is lower than that of the SCT circuits. This property can be of interest in both the derivation of analytical and numerical solutions. A simple radial system is used to exemplify the proposed methodology.

EnergiesVol. 19(11)
Politecnico di Milano (IT)
Openalex Percentile: Top 9%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.