Biomechanical Behavior of Composite Bone–Osteosynthesis Constructs in Complex Proximal Humerus Fractures: A Synergistic Experimental and Finite Element Approach

This study evaluates the mechanical behavior of bone-implant assemblies used in treating complex proximal humerus fractures, a clinical challenge due to the anisotropic nature of bone and variability in patient-specific conditions. The aim of this study was to compare the stability and stress distribution of three fixation methods: polyaxial locking plates, monoaxial locking plates, and intramedullary nails. Using 4th-generation composite humerus models, a four-part fracture (Neer IV) was simulated. The assemblies underwent axial compression testing using a universal testing machine, complemented by finite element analysis (FEA) and stereomicroscopy. The results indicate that while both plate types exhibited similar mechanical behavior—with stiffness values around 113–115 N/mm and failure initiated by plastic deformation of the implant—the intramedullary nail configuration demonstrated higher stiffness values under the tested experimental conditions (1084 N/mm), approximately 9.5 times higher than that of the plates. However, the nail assembly failed through brittle fracture of the bone rather than implant deformation. We conclude that while the intramedullary nail configuration demonstrated higher stiffness under the tested experimental conditions, its performance is heavily dependent on bone quality. In contrast, locking plates may provide a more gradual load-transfer behavior by transferring a greater proportion of the mechanical load to the implant, potentially making them more suitable for osteoporotic bone conditions, where reducing excessive stress concentration within the bone tissue may be beneficial.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-05-27
DOI
https://doi.org/10.3390/bioengineering13060625
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Behavior of Composite Bone–Osteosynthesis Constructs in Complex Proximal Humerus Fractures: A Synergistic Experimental and Finite Element Approach

Mihnea Theodor Sîrbu, Diana Bulgaru Iliescu, Simona Irina Damian, Andrei Scripcaru et al.
Bioengineering
Shoulder Injury and Treatment
article

Biomechanical Behavior of Composite Bone–Osteosynthesis Constructs in Complex Proximal Humerus Fractures: A Synergistic Experimental and Finite Element Approach

Mihnea Theodor Sîrbu, Diana Bulgaru Iliescu, Simona Irina Damian, Andrei Scripcaru, VASILE IULIAN ANTONIAC, Tatiana Iov, Norin Forna, Paul-Dan Sîrbu, Mădălina Maria Diac, Veronica Scripcaru
article en

Abstract

This study evaluates the mechanical behavior of bone-implant assemblies used in treating complex proximal humerus fractures, a clinical challenge due to the anisotropic nature of bone and variability in patient-specific conditions. The aim of this study was to compare the stability and stress distribution of three fixation methods: polyaxial locking plates, monoaxial locking plates, and intramedullary nails. Using 4th-generation composite humerus models, a four-part fracture (Neer IV) was simulated. The assemblies underwent axial compression testing using a universal testing machine, complemented by finite element analysis (FEA) and stereomicroscopy. The results indicate that while both plate types exhibited similar mechanical behavior—with stiffness values around 113–115 N/mm and failure initiated by plastic deformation of the implant—the intramedullary nail configuration demonstrated higher stiffness values under the tested experimental conditions (1084 N/mm), approximately 9.5 times higher than that of the plates. However, the nail assembly failed through brittle fracture of the bone rather than implant deformation. We conclude that while the intramedullary nail configuration demonstrated higher stiffness under the tested experimental conditions, its performance is heavily dependent on bone quality. In contrast, locking plates may provide a more gradual load-transfer behavior by transferring a greater proportion of the mechanical load to the implant, potentially making them more suitable for osteoporotic bone conditions, where reducing excessive stress concentration within the bone tissue may be beneficial.

BioengineeringVol. 13(6)
Grigore T. Popa University of Medicine and Pharmacy (RO), "Dunarea de Jos" University of Galati (RO), Apollonia University (RO), Universitatea Națională de Știință și Tehnologie Politehnica București (RO)
Openalex Percentile: Top 5%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.