Quantitative Assessment of Aortic Arch Conformability and Clinical Outcomes Following Thoracic Endovascular Aortic Repair

PURPOSE: Thoracic stent graft conformability is believed to provide mechanical advantages during thoracic endovascular aortic repair (TEVAR); however, quantitative evidence and associated clinical outcomes remain limited. This study aimed to assess stent graft conformability across varying aortic arch configurations and pathologies, and to evaluate short- and mid-term technical and clinical outcomes. MATERIALS AND METHODS: A retrospective, single-centre review was conducted of TEVAR procedures performed using the GORE cTAG stent graft over a seven-year period. Pre- and post-deployment anatomical measurements were obtained using Endosize® software to assess conformability across a range of aortic arch morphologies and aortic syndromes. Conformability was defined as a < 10% change in predefined anatomical parameters, including aortic arch angle and proximal landing zone (PLZ) angle. Demographic data, mortality, complications, incidence of bird beaking, and reintervention rates were analysed. RESULTS: Of 189 TEVAR procedures performed during the study period, 111 met inclusion criteria and utilised the GORE cTAG stent graft. High conformability was observed following intervention, with 79% of patients demonstrating < 10% change in aortic arch angle and 88% demonstrating < 10% change in PLZ angle. Bird beaking occurred in 10.8% of patients. The overall reintervention rate was 5.4%, with greater angular changes significantly associated with reintervention (p = 0.039). Overall survival rates at 30 days, 1 year, and 5 years were 95%, 86%, and 80%, respectively. CONCLUSION: The GORE cTAG stent graft demonstrates high conformability across diverse aortic arch morphologies and pathologies, which is associated with favourable short- and mid-term technical and clinical outcomes.

Authors

Institutions

Publication Details

Journal
CardioVascular and Interventional Radiology
Published
2026-05-27
DOI
https://doi.org/10.1007/s00270-026-04481-9
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Assessment of Aortic Arch Conformability and Clinical Outcomes Following Thoracic Endovascular Aortic Repair

Colin Bicknell, Richard Gibbs, Celia Riga, Safa Salim et al.
CardioVascular and Interventional Radiology
Aortic Disease and Treatment Approaches
article

Quantitative Assessment of Aortic Arch Conformability and Clinical Outcomes Following Thoracic Endovascular Aortic Repair

Colin Bicknell, Richard Gibbs, Celia Riga, Safa Salim, Sara Ffrench-Constant, Michael Jenkins, Mohamad Hamady, Neda Oskooee
article en

Abstract

PURPOSE: Thoracic stent graft conformability is believed to provide mechanical advantages during thoracic endovascular aortic repair (TEVAR); however, quantitative evidence and associated clinical outcomes remain limited. This study aimed to assess stent graft conformability across varying aortic arch configurations and pathologies, and to evaluate short- and mid-term technical and clinical outcomes. MATERIALS AND METHODS: A retrospective, single-centre review was conducted of TEVAR procedures performed using the GORE cTAG stent graft over a seven-year period. Pre- and post-deployment anatomical measurements were obtained using Endosize® software to assess conformability across a range of aortic arch morphologies and aortic syndromes. Conformability was defined as a < 10% change in predefined anatomical parameters, including aortic arch angle and proximal landing zone (PLZ) angle. Demographic data, mortality, complications, incidence of bird beaking, and reintervention rates were analysed. RESULTS: Of 189 TEVAR procedures performed during the study period, 111 met inclusion criteria and utilised the GORE cTAG stent graft. High conformability was observed following intervention, with 79% of patients demonstrating < 10% change in aortic arch angle and 88% demonstrating < 10% change in PLZ angle. Bird beaking occurred in 10.8% of patients. The overall reintervention rate was 5.4%, with greater angular changes significantly associated with reintervention (p = 0.039). Overall survival rates at 30 days, 1 year, and 5 years were 95%, 86%, and 80%, respectively. CONCLUSION: The GORE cTAG stent graft demonstrates high conformability across diverse aortic arch morphologies and pathologies, which is associated with favourable short- and mid-term technical and clinical outcomes.

CardioVascular and Interventional Radiology
Imperial College Healthcare NHS Trust (GB), Imperial College London (GB)
Good health and well-being
Openalex Percentile: Top 8%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.