Virtual Noncontrast Images Derived From Photon-Counting CT Enhance Inter-Reader Reproducibility of Myocardial ECV Measurement in Patients With Cardiac Devices

OBJECTIVE: The standard 2-scan computed tomography (CT) for quantifying the extracellular volume fraction (ECV) of the left ventricle is limited by misregistration errors, particularly in patients with atrial fibrillation (AF) or cardiac implants such as prosthetic valves and/or cardiac implantable electronic devices (CIEDs). This study aimed to evaluate whether a single-scan virtual noncontrast (VNC) method using photon-counting CT (PCCT) improves the reproducibility of measurement compared with the standard subtraction method in these challenging patient populations. METHODS: We retrospectively analyzed 59 patients undergoing PCCT, stratified into the following 3 groups: control (n=20), AF (n=20), and cardiac implants, including prosthetic valves and/or CIEDs (n=19). Myocardial ECV was quantified using both standard subtraction and VNC methods. Reproducibility was assessed by intraclass correlation coefficients (ICCs) and mean absolute error. RESULTS: In the cardiac implant group, the VNC method demonstrated a significantly lower interobserver mean absolute error compared with the standard subtraction method (1.66% vs. 2.54%, P=0.029). No significant differences were observed in the AF (1.35% vs. 1.54%, P=0.648) or control (1.39% vs. 1.68%, P=0.674) groups. The VNC method demonstrated good to excellent interobserver (all ICCs >0.89) and intraobserver (all ICCs >0.90) agreement. Intraobserver agreement was also excellent for both methods, with no significant difference between them. CONCLUSIONS: The PCCT-derived VNC method significantly improves interobserver reproducibility of ECV measurement in patients with cardiac devices, establishing it as a more reproducible technique for myocardial tissue characterization in this challenging population.

Authors

Institutions

Publication Details

Journal
Journal of Computer Assisted Tomography
Published
2026-05-27
DOI
https://doi.org/10.1097/rct.0000000000001880
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Virtual Noncontrast Images Derived From Photon-Counting CT Enhance Inter-Reader Reproducibility of Myocardial ECV Measurement in Patients With Cardiac Devices

Hiroto Hada, Yoshinori Kanno, M Ohmori, Yosuke Yamakami et al.
Journal of Computer Assisted Tomography
Advanced X-ray and CT Imaging
article

Virtual Noncontrast Images Derived From Photon-Counting CT Enhance Inter-Reader Reproducibility of Myocardial ECV Measurement in Patients With Cardiac Devices

Hiroto Hada, Yoshinori Kanno, M Ohmori, Yosuke Yamakami, Takahiro Tsunoda, Tetsuo Sasano, Kensuke Hirasawa, Taishi Yonetsu, Ken Takahashi
article en

Abstract

OBJECTIVE: The standard 2-scan computed tomography (CT) for quantifying the extracellular volume fraction (ECV) of the left ventricle is limited by misregistration errors, particularly in patients with atrial fibrillation (AF) or cardiac implants such as prosthetic valves and/or cardiac implantable electronic devices (CIEDs). This study aimed to evaluate whether a single-scan virtual noncontrast (VNC) method using photon-counting CT (PCCT) improves the reproducibility of measurement compared with the standard subtraction method in these challenging patient populations. METHODS: We retrospectively analyzed 59 patients undergoing PCCT, stratified into the following 3 groups: control (n=20), AF (n=20), and cardiac implants, including prosthetic valves and/or CIEDs (n=19). Myocardial ECV was quantified using both standard subtraction and VNC methods. Reproducibility was assessed by intraclass correlation coefficients (ICCs) and mean absolute error. RESULTS: In the cardiac implant group, the VNC method demonstrated a significantly lower interobserver mean absolute error compared with the standard subtraction method (1.66% vs. 2.54%, P=0.029). No significant differences were observed in the AF (1.35% vs. 1.54%, P=0.648) or control (1.39% vs. 1.68%, P=0.674) groups. The VNC method demonstrated good to excellent interobserver (all ICCs >0.89) and intraobserver (all ICCs >0.90) agreement. Intraobserver agreement was also excellent for both methods, with no significant difference between them. CONCLUSIONS: The PCCT-derived VNC method significantly improves interobserver reproducibility of ECV measurement in patients with cardiac devices, establishing it as a more reproducible technique for myocardial tissue characterization in this challenging population.

Journal of Computer Assisted Tomography
University of Tokyo Hospital (JP)
Openalex Percentile: Top 10%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.