Quantification of Gaze-Dependent Corrective Errors With Fresnel Prisms: Implications for Strabismus Management

Purpose: Fresnel prisms are widely used to manage strabismus. Although prism power is typically selected based on the deviation in the primary gaze position, actual deflection varies with the gaze direction because the angle of incidence changes. This study quantified gaze-dependent corrective errors in the secondary and tertiary positions. Methods: Fresnel prisms (10Δ-40Δ) were mounted on a two-axis rotation stage. Deflection was measured by projecting a laser spot onto a tangent screen 100 cm away while rotating the prisms horizontally and/or vertically (±30°). Two configurations were tested: eyeward prism serration (EPS) and outward prism serration (OPS). Geometric modeling was used to predict the deflection of a prism attached to a spectacle lens, and corrective errors across the gaze field were visualized as contour maps using Kriging interpolation. Results: Corrective errors varied with prism power, gaze position, and application method (EPS vs. OPS; factorial ANOVA, P < 0.05). Prisms > 20Δ exhibited substantial, spatially complex errors. In the EPS configuration, horizontal gaze shifts toward the apex caused rapidly increasing overcorrection, whereas shifts toward the base led to undercorrection. In the OPS configuration, this gradient was reversed on the horizontal axis (P < 0.0001). Vertical gaze shifts not only amplified the horizontal corrective effects but also created unintended vertical components (perpendicular to the principal section). Conclusions: Fresnel prisms introduce nonlinear, gaze-dependent corrective errors despite the full correction of the strabismic deviation in the primary position. Recognition of these optical properties may help optimize therapeutic outcomes and enhance diagnostic accuracy.

Authors

Institutions

Publication Details

Journal
Investigative Ophthalmology & Visual Science
Published
2026-05-27
DOI
https://doi.org/10.1167/iovs.67.5.68
Primary Topic
Ophthalmology and Eye Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of Gaze-Dependent Corrective Errors With Fresnel Prisms: Implications for Strabismus Management

Eizo Tanaka, Satoshi Hasebe, Shin Morisawa, Tomoki Tokutake et al.
Investigative Ophthalmology & Visual Science
Ophthalmology and Eye Disorders
article

Quantification of Gaze-Dependent Corrective Errors With Fresnel Prisms: Implications for Strabismus Management

Eizo Tanaka, Satoshi Hasebe, Shin Morisawa, Tomoki Tokutake, Yuki Morizane
article en

Abstract

Purpose: Fresnel prisms are widely used to manage strabismus. Although prism power is typically selected based on the deviation in the primary gaze position, actual deflection varies with the gaze direction because the angle of incidence changes. This study quantified gaze-dependent corrective errors in the secondary and tertiary positions. Methods: Fresnel prisms (10Δ-40Δ) were mounted on a two-axis rotation stage. Deflection was measured by projecting a laser spot onto a tangent screen 100 cm away while rotating the prisms horizontally and/or vertically (±30°). Two configurations were tested: eyeward prism serration (EPS) and outward prism serration (OPS). Geometric modeling was used to predict the deflection of a prism attached to a spectacle lens, and corrective errors across the gaze field were visualized as contour maps using Kriging interpolation. Results: Corrective errors varied with prism power, gaze position, and application method (EPS vs. OPS; factorial ANOVA, P < 0.05). Prisms > 20Δ exhibited substantial, spatially complex errors. In the EPS configuration, horizontal gaze shifts toward the apex caused rapidly increasing overcorrection, whereas shifts toward the base led to undercorrection. In the OPS configuration, this gradient was reversed on the horizontal axis (P < 0.0001). Vertical gaze shifts not only amplified the horizontal corrective effects but also created unintended vertical components (perpendicular to the principal section). Conclusions: Fresnel prisms introduce nonlinear, gaze-dependent corrective errors despite the full correction of the strabismic deviation in the primary position. Recognition of these optical properties may help optimize therapeutic outcomes and enhance diagnostic accuracy.

Investigative Ophthalmology & Visual ScienceVol. 67(5)
Okayama University (JP), Kawasaki Medical School (JP)
Openalex Percentile: Top 7%
Ophthalmology and Eye Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.