Comparative Experimental Assessment of Photovoltaic Panel Stability Under Moderate Freeze–Thaw Thermal Cycling

This study presents an experimental investigation on the electrical performance, durability, and sustainability of different types of photovoltaic panels subjected to controlled climatic conditions and simulated solar radiation. Four photovoltaic technologies were analyzed, including monocrystalline, polycrystalline, and two semi-flexible panels, to evaluate their behavior under thermal stress. The experimental methodology consisted of repeated freeze–thaw cycles conducted in a double climatic chamber, with temperatures varying between −18 °C and +5 °C. Each panel was subjected to up to 500 cycles designed to reproduce repeated freeze–thaw environmental conditions representative of moderate cold-climate operation. At predefined intervals, the electrical characteristics of the panels were assessed using a solar radiation simulator based on high-pressure mercury vapor lamps, ensuring controlled and repeatable irradiation conditions. The results indicate that all tested panels exhibited relatively stable open-circuit voltage and output current values throughout the investigated thermal cycling interval, with only minor fluctuations observed during the experimental measurements. No visible macroscopic structural degradation and no major variations in the monitored electrical parameters were identified during the investigated testing conditions. Semi-flexible panels demonstrated comparable behavior to rigid panels, highlighting their potential for applications requiring mechanical adaptability. From a sustainability perspective, the observed durability and performance stability contribute to extending the operational lifetime of photovoltaic systems, reducing maintenance needs and material replacement rates. The findings provide comparative experimental observations regarding the evolution of selected electrical parameters under repeated moderate freeze–thaw exposure conditions.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-05-27
DOI
https://doi.org/10.3390/su18115404
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Experimental Assessment of Photovoltaic Panel Stability Under Moderate Freeze–Thaw Thermal Cycling

Răzvan-Andrei Polcovnicu, Nicolae Ţăranu, Cătălin Onuțu, Nelu-Cristian Cherecheș et al.
Sustainability
Solar Thermal and Photovoltaic Systems
article

Comparative Experimental Assessment of Photovoltaic Panel Stability Under Moderate Freeze–Thaw Thermal Cycling

Răzvan-Andrei Polcovnicu, Nicolae Ţăranu, Cătălin Onuțu, Nelu-Cristian Cherecheș, D. Ungureanu, Sebastian-Valeriu Hudișteanu, Marius Alexa, Alexandru-Florin Mustiață, Iuliana Hudișteanu, Florin-Emilian Țurcanu
article en

Abstract

This study presents an experimental investigation on the electrical performance, durability, and sustainability of different types of photovoltaic panels subjected to controlled climatic conditions and simulated solar radiation. Four photovoltaic technologies were analyzed, including monocrystalline, polycrystalline, and two semi-flexible panels, to evaluate their behavior under thermal stress. The experimental methodology consisted of repeated freeze–thaw cycles conducted in a double climatic chamber, with temperatures varying between −18 °C and +5 °C. Each panel was subjected to up to 500 cycles designed to reproduce repeated freeze–thaw environmental conditions representative of moderate cold-climate operation. At predefined intervals, the electrical characteristics of the panels were assessed using a solar radiation simulator based on high-pressure mercury vapor lamps, ensuring controlled and repeatable irradiation conditions. The results indicate that all tested panels exhibited relatively stable open-circuit voltage and output current values throughout the investigated thermal cycling interval, with only minor fluctuations observed during the experimental measurements. No visible macroscopic structural degradation and no major variations in the monitored electrical parameters were identified during the investigated testing conditions. Semi-flexible panels demonstrated comparable behavior to rigid panels, highlighting their potential for applications requiring mechanical adaptability. From a sustainability perspective, the observed durability and performance stability contribute to extending the operational lifetime of photovoltaic systems, reducing maintenance needs and material replacement rates. The findings provide comparative experimental observations regarding the evolution of selected electrical parameters under repeated moderate freeze–thaw exposure conditions.

SustainabilityVol. 18(11)
Academia Oamenilor de Știință din România (RO), Gheorghe Asachi Technical University of Iași (RO)
Openalex Percentile: Top 17%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.