Surgical outcomes and postoperative complications of robotic versus conventional nipple-sparing mastectomy in breast cancer: A meta-analysis.

585 Background: Breast cancer is the most common type of cancer, affecting millions of women worldwide. Nipple-sparing mastectomy has emerged as a technique that leaves most of the healthy breast skin, areola, and nipple. This technique is widely used but there is little evidence comparing conventional and robotic nipple-sparing mastectomy. This meta-analysis aimed to compare the efficacy, safety, and postoperative complications of conventional and robotic nipple-sparing mastectomy. Methods: A systematic search of PubMed, Scopus, Web of Science, and the Cochrane Library was conducted to identify studies comparing robotic and conventional nipple-sparing mastectomy. The primary outcome was nipple and skin necrosis; secondary outcomes included operative time and Clavien-Dindo Grade III complications. Pooled estimates were calculated using a random-effects model, and heterogeneity was assessed using the I2 statistic. Results: A total of nine studies encompassing 1,220 participants (423 in the robotic group and 797 in the conventional group) were included in the final analysis. Robotic nipple-sparing mastectomy (RNSM) was associated with a significantly lower risk of nipple and skin necrosis compared to conventional nipple-sparing mastectomy (CNSM), with a pooled odds ratio of 0.47 (95% CI: 0.26–0.86; P = 0.01) and low heterogeneity (I2 = 20.5%). Conversely, RNSM was associated with a significantly longer operative time, with a weighted mean difference of 52.86 minutes (95% CI: 20.28–85.43; P = 0.001) and substantial heterogeneity (I2 = 96%). Regarding safety, there was no statistically significant difference in Clavien-Dindo Grade III complications between the two techniques (OR = 0.60; 95% CI: 0.35–1.05; P = 0.07; I2 = 0%), although the results showed a trend favoring the robotic approach. Conclusions: Robotic nipple-sparing mastectomy demonstrates a superior safety profile regarding ischemic complications, significantly reducing the risk of nipple and skin necrosis compared to the conventional approach. However, it is associated with longer operative times. The incidence of major complications (Grade III) is comparable between both techniques.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Oncology
Published
2026-05-27
DOI
https://doi.org/10.1200/jco.2026.44.16_suppl.585
Primary Topic
Breast Implant and Reconstruction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surgical outcomes and postoperative complications of robotic versus conventional nipple-sparing mastectomy in breast cancer: A meta-analysis.

Zahra Rehman, Fatima Rasool, Saba Musleh Ud Din, Hafiza Maheen Fatima et al.
Journal of Clinical Oncology
Breast Implant and Reconstruction
article

Surgical outcomes and postoperative complications of robotic versus conventional nipple-sparing mastectomy in breast cancer: A meta-analysis.

Zahra Rehman, Fatima Rasool, Saba Musleh Ud Din, Hafiza Maheen Fatima, Ammad Abid, Fahad Amin, Sundas Ali
article en

Abstract

585 Background: Breast cancer is the most common type of cancer, affecting millions of women worldwide. Nipple-sparing mastectomy has emerged as a technique that leaves most of the healthy breast skin, areola, and nipple. This technique is widely used but there is little evidence comparing conventional and robotic nipple-sparing mastectomy. This meta-analysis aimed to compare the efficacy, safety, and postoperative complications of conventional and robotic nipple-sparing mastectomy. Methods: A systematic search of PubMed, Scopus, Web of Science, and the Cochrane Library was conducted to identify studies comparing robotic and conventional nipple-sparing mastectomy. The primary outcome was nipple and skin necrosis; secondary outcomes included operative time and Clavien-Dindo Grade III complications. Pooled estimates were calculated using a random-effects model, and heterogeneity was assessed using the I2 statistic. Results: A total of nine studies encompassing 1,220 participants (423 in the robotic group and 797 in the conventional group) were included in the final analysis. Robotic nipple-sparing mastectomy (RNSM) was associated with a significantly lower risk of nipple and skin necrosis compared to conventional nipple-sparing mastectomy (CNSM), with a pooled odds ratio of 0.47 (95% CI: 0.26–0.86; P = 0.01) and low heterogeneity (I2 = 20.5%). Conversely, RNSM was associated with a significantly longer operative time, with a weighted mean difference of 52.86 minutes (95% CI: 20.28–85.43; P = 0.001) and substantial heterogeneity (I2 = 96%). Regarding safety, there was no statistically significant difference in Clavien-Dindo Grade III complications between the two techniques (OR = 0.60; 95% CI: 0.35–1.05; P = 0.07; I2 = 0%), although the results showed a trend favoring the robotic approach. Conclusions: Robotic nipple-sparing mastectomy demonstrates a superior safety profile regarding ischemic complications, significantly reducing the risk of nipple and skin necrosis compared to the conventional approach. However, it is associated with longer operative times. The incidence of major complications (Grade III) is comparable between both techniques.

Journal of Clinical OncologyVol. 44(16_suppl)
King Edward Medical University (PK), Memorial Healthcare System (US), Masaryk Memorial Cancer Institute (CZ)
Good health and well-being
Openalex Percentile: Top 6%
Breast Implant and Reconstruction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.