A Highly Sensitive Dual-Cathodic Ratiometric Electrochemiluminescence Biosensor Based on Functionalized Copper Nanoclusters and Nitrogen- and Sulfur-Codoped Carbon Dots for the Detection of miRNA-155

In most ratiometric electrochemiluminescence (ECL) sensors, the utilization of different co-reactants for anodic and cathodic ECL luminophores, along with a broad potential scanning range, restricts their practical applications. Herein, we first reported dual-cathodic potential-resolved ECL from nitrogen/sulfur-codoped carbon dots (N,S-CDs) and mercaptopropionic acid-functionalized copper nanoclusters (MPA-Cu NCs) using their common co-reactant K2S2O8 within a potential range of 0 to −2 V, and developed a ratiometric ECL biosensor for miRNA-155 analysis. Initially, the ECL peak of MPA-Cu NCs at approximately −2 V on the electrode was quenched through resonance energy transfer (RET) by methylene blue. Subsequently, trace target miRNA-155 was converted into abundant output DNA via a DNA walker mechanism. In the presence of Pb2+, partial DNA was cleaved to remove methylene blue, thereby restoring the ECL intensity of MPA-Cu NCs. Furthermore, the cleaved DNA fragments sparked rolling circle amplification (RCA), which ultimately facilitated the loading of N,S-CDs onto the electrode surface, generating an ECL peak at approximately −1 V. As the concentration of miRNA-155 increased, both ECL signals rose simultaneously but with different magnitudes. The fabricated ratiometric ECL sensor achieved a linear detection range for miRNA-155 from 10 aM to 0.1 nM, with a limit of detection of 2.91 aM. Overall, this study offers a new strategy for constructing dual-cathodic ratiometric ECL biosensors and provides a promising approach for early disease diagnosis.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2026-05-27
DOI
https://doi.org/10.3390/chemosensors14060124
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Highly Sensitive Dual-Cathodic Ratiometric Electrochemiluminescence Biosensor Based on Functionalized Copper Nanoclusters and Nitrogen- and Sulfur-Codoped Carbon Dots for the Detection of miRNA-155

Ming-Yu Zhong, Hao-Xue Li, Deng Ming-zhu, Yue Gu et al.
Chemosensors
Advanced biosensing and bioanalysis techniques
article

A Highly Sensitive Dual-Cathodic Ratiometric Electrochemiluminescence Biosensor Based on Functionalized Copper Nanoclusters and Nitrogen- and Sulfur-Codoped Carbon Dots for the Detection of miRNA-155

Ming-Yu Zhong, Hao-Xue Li, Deng Ming-zhu, Yue Gu, Cheng-Cheng Li, Li Mi, Hao He, Meng-Li Li, Jie Lu, Yin-Zhu Wang, Zheng Xu, Fang Zhang, Guo-Song Chen
article en

Abstract

In most ratiometric electrochemiluminescence (ECL) sensors, the utilization of different co-reactants for anodic and cathodic ECL luminophores, along with a broad potential scanning range, restricts their practical applications. Herein, we first reported dual-cathodic potential-resolved ECL from nitrogen/sulfur-codoped carbon dots (N,S-CDs) and mercaptopropionic acid-functionalized copper nanoclusters (MPA-Cu NCs) using their common co-reactant K2S2O8 within a potential range of 0 to −2 V, and developed a ratiometric ECL biosensor for miRNA-155 analysis. Initially, the ECL peak of MPA-Cu NCs at approximately −2 V on the electrode was quenched through resonance energy transfer (RET) by methylene blue. Subsequently, trace target miRNA-155 was converted into abundant output DNA via a DNA walker mechanism. In the presence of Pb2+, partial DNA was cleaved to remove methylene blue, thereby restoring the ECL intensity of MPA-Cu NCs. Furthermore, the cleaved DNA fragments sparked rolling circle amplification (RCA), which ultimately facilitated the loading of N,S-CDs onto the electrode surface, generating an ECL peak at approximately −1 V. As the concentration of miRNA-155 increased, both ECL signals rose simultaneously but with different magnitudes. The fabricated ratiometric ECL sensor achieved a linear detection range for miRNA-155 from 10 aM to 0.1 nM, with a limit of detection of 2.91 aM. Overall, this study offers a new strategy for constructing dual-cathodic ratiometric ECL biosensors and provides a promising approach for early disease diagnosis.

ChemosensorsVol. 14(6)
Nanjing Tech University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 10%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.