Understanding the precondition of microbially induced corrosion from surface acidification of alkali-activated slag pastes

Microbially induced corrosion (MIC) has been recognized as a major cause of performance degradation and service life reduction of concrete sewer system. However, the mechanisms for early-stage corrosion and bacterial attachment are not fully understood yet. Aiming at the correlation between surface acidification and the following MIC process, this study investigated the early-stage corrosion of alkali-activated slag (AAS) pastes under organic acid attack (acetic and propionic acids at pH 6 and 4) considering the effect of precursor, alkali content and modulus of activator. The changes in mechanical property, appearance, and microstructure of AAS were analyzed through three-point bending strength test, visual observation, solution and surface pH monitoring, combined with microscale characterizations. The results demonstrate that two organic acids effectively regulate the surface pH of AAS to a range conducive for bacterial attachment. Specifically, pH 4 solutions reduced the surface pH to 4~5 within 35 d, which triggered severe decalcification, hydration product decomposition and pore structure coarsening, leading to a mechanical strength loss of over 64%. In contrast, pH 6 solutions decreased the surface pH to 8~9, but it had a slight impact on the appearance, strength, and microstructure of AAS. At the same pH value, acetic acid solution exhibited slightly stronger corrosivity than that of propionic acid. The findings provide insights into the corrosion process before bacterial attachment and the precondition of MIC on AAS, which facilitates more precisely conducting accelerated simulation tests for large-scale MIC.

Authors

Institutions

Publication Details

Journal
Case Studies in Construction Materials
Published
2026-05-27
DOI
https://doi.org/10.1016/j.cscm.2026.e06183
Primary Topic
Microbial Applications in Construction Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Understanding the precondition of microbially induced corrosion from surface acidification of alkali-activated slag pastes

Binghan Xue, Mingrui Du, Shenghao Zuo, Lingxu Gan et al.
Case Studies in Construction Materials
Microbial Applications in Construction Materials
article

Understanding the precondition of microbially induced corrosion from surface acidification of alkali-activated slag pastes

Binghan Xue, Mingrui Du, Shenghao Zuo, Lingxu Gan, Jianwei Lei, Kai Zhang, Huichao Sun
article en

Abstract

Microbially induced corrosion (MIC) has been recognized as a major cause of performance degradation and service life reduction of concrete sewer system. However, the mechanisms for early-stage corrosion and bacterial attachment are not fully understood yet. Aiming at the correlation between surface acidification and the following MIC process, this study investigated the early-stage corrosion of alkali-activated slag (AAS) pastes under organic acid attack (acetic and propionic acids at pH 6 and 4) considering the effect of precursor, alkali content and modulus of activator. The changes in mechanical property, appearance, and microstructure of AAS were analyzed through three-point bending strength test, visual observation, solution and surface pH monitoring, combined with microscale characterizations. The results demonstrate that two organic acids effectively regulate the surface pH of AAS to a range conducive for bacterial attachment. Specifically, pH 4 solutions reduced the surface pH to 4~5 within 35 d, which triggered severe decalcification, hydration product decomposition and pore structure coarsening, leading to a mechanical strength loss of over 64%. In contrast, pH 6 solutions decreased the surface pH to 8~9, but it had a slight impact on the appearance, strength, and microstructure of AAS. At the same pH value, acetic acid solution exhibited slightly stronger corrosivity than that of propionic acid. The findings provide insights into the corrosion process before bacterial attachment and the precondition of MIC on AAS, which facilitates more precisely conducting accelerated simulation tests for large-scale MIC.

Case Studies in Construction MaterialsVol. 24
Zhengzhou University (CN), Yellow River Institute of Hydraulic Research (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation
Openalex Percentile: Top 9%
Microbial Applications in Construction Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.