Ex vivo accuracy of three electronic apex locators under various irrigants

Evidence on the X-Smart Pro + for apical constriction detection under different irrigants remains limited. This ex vivo study compared X-Smart Pro+, Root ZX Mini, and Propex Pixi in 36 extracted single-rooted teeth standardized to 17 mm. Real working length (RWL) was determined microscopically, and electronic measurements were obtained in an alginate model under saline, 2.5% sodium hypochlorite, 17% EDTA, and 2% chlorhexidine. X-Smart Pro+ was assessed at two distinct points, corresponding to the 4th and 7th green LEDs (GL4 and GL7). Mean deviations from the RWL ranged from - 0.36 to 0.40 mm, and all devices yielded mean measurements within ± 0.5 mm. Root ZX Mini showed the highest overall accuracy by the ± 0.5 mm criterion, whereas X-Smart Pro+ GL4 showed a smaller mean deviation in saline and significantly improved accuracy in 17% EDTA (P < 0.05). GL4 measurements were generally closer to the RWL than GL7, except in NaOCl. Irrigant type did not significantly affect most measurements (P > 0.05). Within the limitations of this ex vivo model, the tested electronic apex locators showed broadly comparable accuracy, and for X-Smart Pro+, GL4 measurements were generally closer to the RWL than GL7.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-27
DOI
https://doi.org/10.1038/s41598-026-54329-y
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ex vivo accuracy of three electronic apex locators under various irrigants

Damla Erkal, Muhammed Ayhan
Scientific Reports
Intraocular Surgery and Lenses
article

Ex vivo accuracy of three electronic apex locators under various irrigants

Damla Erkal, Muhammed Ayhan
article en

Abstract

Evidence on the X-Smart Pro + for apical constriction detection under different irrigants remains limited. This ex vivo study compared X-Smart Pro+, Root ZX Mini, and Propex Pixi in 36 extracted single-rooted teeth standardized to 17 mm. Real working length (RWL) was determined microscopically, and electronic measurements were obtained in an alginate model under saline, 2.5% sodium hypochlorite, 17% EDTA, and 2% chlorhexidine. X-Smart Pro+ was assessed at two distinct points, corresponding to the 4th and 7th green LEDs (GL4 and GL7). Mean deviations from the RWL ranged from - 0.36 to 0.40 mm, and all devices yielded mean measurements within ± 0.5 mm. Root ZX Mini showed the highest overall accuracy by the ± 0.5 mm criterion, whereas X-Smart Pro+ GL4 showed a smaller mean deviation in saline and significantly improved accuracy in 17% EDTA (P < 0.05). GL4 measurements were generally closer to the RWL than GL7, except in NaOCl. Irrigant type did not significantly affect most measurements (P > 0.05). Within the limitations of this ex vivo model, the tested electronic apex locators showed broadly comparable accuracy, and for X-Smart Pro+, GL4 measurements were generally closer to the RWL than GL7.

Scientific Reports
Burdur Mehmet Akif Ersoy Üniversitesi (TR)
Zero hunger
Openalex Percentile: Top 6%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.