Preclinical in vivo results of the new generation coated FRED Flow Diverter

BACKGROUND: The introduction of coatings on flow diverter stents (FD) marks a significant evolution in neurovascular intervention for aneurysm embolization. FDs represent a major innovation in the treatment of intracranial aneurysms by promoting endothelial healing and reconstructing the parent artery. FRED Omega is a new generation FD featuring a poly(2-methoxyethyl acrylate) (PMEA)-based surface modification designed to reduce thrombogenicity while maintaining endothelialization. This preclinical study assessed the biocompatibility and aneurysm occlusion efficacy of FRED Omega in a rabbit elastase aneurysm model. METHODS: Eight New Zealand white rabbits were implanted with FRED Omega across elastase-induced aneurysms and maintained on single antiplatelet therapy (SAPT). Angiography, cone-beam computed tomography, and optical coherence tomography (OCT) were used to evaluate device performance. Histology, environmental scanning electron microscopy (ESEM) and multiphoton microscopy analyses (MM) were conducted on explanted tissues. RESULTS: At day 28, 7 aneurysms (87.50%, 7/8) achieved complete or near-complete occlusion. All implants remained stable over the time study. All vessels were clear of thrombus with no flow abnormalities nor sign of intimal hyperplasia. OCT confirmed these data associated with good wall apposition for all stents (100.00%, 8/8). Histology and ESEM showed well-organized new tissue on each FD (100.00%, 8/8), compared to 75.00% for MM (6/8, 75.00%). Quantitative measurement of neointimal ratio was excellent with an average of 0.068. CONCLUSION: FRED Omega demonstrated promising preclinical performance with enhanced endothelialization and aneurysm occlusion in a validated animal model under SAPT.

Authors

Institutions

Publication Details

Journal
American Journal of Neuroradiology
Published
2026-05-23
DOI
https://doi.org/10.3174/ajnr.a9431
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preclinical in vivo results of the new generation coated FRED Flow Diverter

Maxime Baudouin, Voa Ratsimbazafy, Faraj Terro, Marie-Laure Perrin et al.
American Journal of Neuroradiology
Mechanical Circulatory Support Devices
article

Preclinical in vivo results of the new generation coated FRED Flow Diverter

Maxime Baudouin, Voa Ratsimbazafy, Faraj Terro, Marie-Laure Perrin, Sylvia M. Bardet, Jérémy Mounier, Géraud Forestier, Daphnée Chandellier, Gregory Sasselina, Claude Couquet, Jonathan Cortese, Charbel Mounayer, Charles Roux, Francesco Diana, Aymeric Rouchaud, Aurélien Le Flahec, Romain Chauvet, Ronak Dholakia, Alexis Belgacem, Nicolas Dubois
article en

Abstract

BACKGROUND: The introduction of coatings on flow diverter stents (FD) marks a significant evolution in neurovascular intervention for aneurysm embolization. FDs represent a major innovation in the treatment of intracranial aneurysms by promoting endothelial healing and reconstructing the parent artery. FRED Omega is a new generation FD featuring a poly(2-methoxyethyl acrylate) (PMEA)-based surface modification designed to reduce thrombogenicity while maintaining endothelialization. This preclinical study assessed the biocompatibility and aneurysm occlusion efficacy of FRED Omega in a rabbit elastase aneurysm model. METHODS: Eight New Zealand white rabbits were implanted with FRED Omega across elastase-induced aneurysms and maintained on single antiplatelet therapy (SAPT). Angiography, cone-beam computed tomography, and optical coherence tomography (OCT) were used to evaluate device performance. Histology, environmental scanning electron microscopy (ESEM) and multiphoton microscopy analyses (MM) were conducted on explanted tissues. RESULTS: At day 28, 7 aneurysms (87.50%, 7/8) achieved complete or near-complete occlusion. All implants remained stable over the time study. All vessels were clear of thrombus with no flow abnormalities nor sign of intimal hyperplasia. OCT confirmed these data associated with good wall apposition for all stents (100.00%, 8/8). Histology and ESEM showed well-organized new tissue on each FD (100.00%, 8/8), compared to 75.00% for MM (6/8, 75.00%). Quantitative measurement of neointimal ratio was excellent with an average of 0.068. CONCLUSION: FRED Omega demonstrated promising preclinical performance with enhanced endothelialization and aneurysm occlusion in a validated animal model under SAPT.

American Journal of Neuroradiology
Centre National de la Recherche Scientifique (FR), Sorbonne Université (FR), Assistance Publique – Hôpitaux de Paris (FR), Université de Limoges (FR)
Openalex Percentile: Top 8%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.