Automated measurement of the minimum macular hole diameter based on optical coherence tomography images

BACKGROUND: Accurate measurement of minimum macular hole (MH) diameter is essential for diagnosis and treatment. The manual measurement approach by ophthalmologists is time-consuming, poorly reproducible, and exhibits high inter-observer variability. Threshold-based methods are sensitive to image quality, and perform inadequately in low-contrast optical coherence tomography (OCT) images. Deep learning can achieve higher measurement accuracy but shows limited generalization capability. METHODS: We propose an automated measurement method comprising three sub-tasks. Specifically, a tailored MH dataset is first created by cropping publicly available OCT images to minimize interference from non-MH regions. Subsequently, an image processing pipeline, which consists of denoising, binarization, morphological operations, and edge detection, is implemented to extract the contours on both sides of MH. Finally, an automated measurement algorithm is designed to locate the closest points on the bilateral contours of MH and thereby calculate the minimum diameter. RESULTS: Extensive experiments are conducted to validate the effectiveness of this research. More concretely, on the public dataset, the [Formula: see text] metric obtained by the proposed method closely aligns with the [Formula: see text] metric. The ADE values are predominantly within 1 pixel, achieving as low as 0.00 in some cases. Simultaneously, the method demonstrates favorable performance in the RDE metric, with values ranging from 0.00% to 3.29%, most of which remain below 2.50%. Furthermore, in clinical testing, the measurement time per individual sample is approximately 4 seconds, indicating high efficiency. CONCLUSIONS: Overall, the comprehensive quantitative and qualitative experimental results confirm the method's commendable accuracy and execution efficiency in measuring the minimum MH diameter, demonstrating its potential value in assisting ophthalmologists with the diagnosis and treatment assessment of MH conditions.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-05-23
DOI
https://doi.org/10.1186/s12886-026-04931-5
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated measurement of the minimum macular hole diameter based on optical coherence tomography images

Jiahao Wei, Fen Zhou, Jin Yao, Jianguo Xu et al.
BMC Ophthalmology
Retinal and Macular Surgery
article

Automated measurement of the minimum macular hole diameter based on optical coherence tomography images

Jiahao Wei, Fen Zhou, Jin Yao, Jianguo Xu, Rong Tan, Jianxin Shen
article en

Abstract

BACKGROUND: Accurate measurement of minimum macular hole (MH) diameter is essential for diagnosis and treatment. The manual measurement approach by ophthalmologists is time-consuming, poorly reproducible, and exhibits high inter-observer variability. Threshold-based methods are sensitive to image quality, and perform inadequately in low-contrast optical coherence tomography (OCT) images. Deep learning can achieve higher measurement accuracy but shows limited generalization capability. METHODS: We propose an automated measurement method comprising three sub-tasks. Specifically, a tailored MH dataset is first created by cropping publicly available OCT images to minimize interference from non-MH regions. Subsequently, an image processing pipeline, which consists of denoising, binarization, morphological operations, and edge detection, is implemented to extract the contours on both sides of MH. Finally, an automated measurement algorithm is designed to locate the closest points on the bilateral contours of MH and thereby calculate the minimum diameter. RESULTS: Extensive experiments are conducted to validate the effectiveness of this research. More concretely, on the public dataset, the [Formula: see text] metric obtained by the proposed method closely aligns with the [Formula: see text] metric. The ADE values are predominantly within 1 pixel, achieving as low as 0.00 in some cases. Simultaneously, the method demonstrates favorable performance in the RDE metric, with values ranging from 0.00% to 3.29%, most of which remain below 2.50%. Furthermore, in clinical testing, the measurement time per individual sample is approximately 4 seconds, indicating high efficiency. CONCLUSIONS: Overall, the comprehensive quantitative and qualitative experimental results confirm the method's commendable accuracy and execution efficiency in measuring the minimum MH diameter, demonstrating its potential value in assisting ophthalmologists with the diagnosis and treatment assessment of MH conditions.

BMC Ophthalmology
Second Affiliated Hospital of Nanjing Medical University (CN), Nanjing Medical University (CN), Nanjing University of Aeronautics and Astronautics (CN)
Openalex Percentile: Top 5%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.