A Comparative Evaluation of the Passivity of Screw-retained Interim Implant-supported Prostheses Fabricated by Additive Manufacturing, Subtractive Manufacturing, and Conventional Techniques

Abstract Purpose: This study aimed to evaluate and compare the passivity and vertical marginal misfit of short-span, screw-retained interim implant-supported prostheses fabricated using three different techniques: Additive manufacturing, subtractive manufacturing, and the conventional technique, to determine the most effective technique for achieving optimal passive fit. Materials and Methods: Thirty interim prostheses ( n = 30) were fabricated for ten patients requiring two implants for rehabilitation of a short edentulous span in the mandibular premolar-molar region. For each patient, three sets of prostheses were fabricated, which were divided into three groups: Group A (additive manufacturing via stereolithography), Group B (subtractive manufacturing via computer-aided designing/computer-aided manufacturing [CAD/CAM] milling), and Group C (conventional technique via heat-cured acrylic resin). A standardized prosthesis design was followed across all groups. Passivity was assessed intraorally through direct visual inspection and tactile perception on a 5-point scale by three blinded observers. Vertical marginal misfit was evaluated using a one-screw test under a stereomicroscope on definitive casts before prosthesis delivery. Data were statistically analyzed using one-way ANOVA and intergroup comparisons. Results: The study revealed a significant difference in passivity among the three groups. Subtractive manufacturing demonstrated the highest level of passivity, with significantly more prostheses receiving “excellent” scores compared to additive and conventional methods ( P = 0.027*). Vertical marginal misfit values were lowest and statistically comparable for additive (5.92 ± 4.59 μm) and subtractive (5.94 ± 5.19 μm) manufacturing, both significantly better than the conventional group (20.73 ± 4.24 μm, P = 0.001*). Passivity differed significantly between subtractive and additive ( P = 0.022*) and subtractive and conventional methods ( P = 0.011*), but showed no significant difference between additive and conventional manufacturing ( P = 0.796). Conclusion: Subtractive manufacturing is the most effective technique for achieving optimal passivity in interim implant-supported prostheses, outperforming both additive manufacturing and conventional techniques. However, both subtractive and additive manufacturing methods yielded comparable results for vertical marginal misfit, with the conventional method showing a greater discrepancy. Therefore, CAD/CAM technology, particularly subtractive manufacturing, should be the preferred approach for fabricating interim prostheses.

Authors

Institutions

Publication Details

Journal
Indian Journal of Dental Sciences
Published
2026-05-22
DOI
https://doi.org/10.4103/ijds.ijds_255_25
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Evaluation of the Passivity of Screw-retained Interim Implant-supported Prostheses Fabricated by Additive Manufacturing, Subtractive Manufacturing, and Conventional Techniques

Bhupender Yadav, Omkar Shetty, Abhishek Nagpal, Jaiveer Yadav et al.
Indian Journal of Dental Sciences
Dental materials and restorations
article

A Comparative Evaluation of the Passivity of Screw-retained Interim Implant-supported Prostheses Fabricated by Additive Manufacturing, Subtractive Manufacturing, and Conventional Techniques

Bhupender Yadav, Omkar Shetty, Abhishek Nagpal, Jaiveer Yadav, Chhavi Sharma, Diksha Singh
article en

Abstract

Abstract Purpose: This study aimed to evaluate and compare the passivity and vertical marginal misfit of short-span, screw-retained interim implant-supported prostheses fabricated using three different techniques: Additive manufacturing, subtractive manufacturing, and the conventional technique, to determine the most effective technique for achieving optimal passive fit. Materials and Methods: Thirty interim prostheses ( n = 30) were fabricated for ten patients requiring two implants for rehabilitation of a short edentulous span in the mandibular premolar-molar region. For each patient, three sets of prostheses were fabricated, which were divided into three groups: Group A (additive manufacturing via stereolithography), Group B (subtractive manufacturing via computer-aided designing/computer-aided manufacturing [CAD/CAM] milling), and Group C (conventional technique via heat-cured acrylic resin). A standardized prosthesis design was followed across all groups. Passivity was assessed intraorally through direct visual inspection and tactile perception on a 5-point scale by three blinded observers. Vertical marginal misfit was evaluated using a one-screw test under a stereomicroscope on definitive casts before prosthesis delivery. Data were statistically analyzed using one-way ANOVA and intergroup comparisons. Results: The study revealed a significant difference in passivity among the three groups. Subtractive manufacturing demonstrated the highest level of passivity, with significantly more prostheses receiving “excellent” scores compared to additive and conventional methods ( P = 0.027*). Vertical marginal misfit values were lowest and statistically comparable for additive (5.92 ± 4.59 μm) and subtractive (5.94 ± 5.19 μm) manufacturing, both significantly better than the conventional group (20.73 ± 4.24 μm, P = 0.001*). Passivity differed significantly between subtractive and additive ( P = 0.022*) and subtractive and conventional methods ( P = 0.011*), but showed no significant difference between additive and conventional manufacturing ( P = 0.796). Conclusion: Subtractive manufacturing is the most effective technique for achieving optimal passivity in interim implant-supported prostheses, outperforming both additive manufacturing and conventional techniques. However, both subtractive and additive manufacturing methods yielded comparable results for vertical marginal misfit, with the conventional method showing a greater discrepancy. Therefore, CAD/CAM technology, particularly subtractive manufacturing, should be the preferred approach for fabricating interim prostheses.

Indian Journal of Dental Sciences
Shree Guru Gobind Singh Tricentenary University (IN)
Openalex Percentile: Top 4%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.