Graphenated polyaniline-doped tungsten oxide nanocomposite sensor for real time determination of phenanthrene

A graphenated polyaniline/tungsten oxide (PANI/WO3/GR) nanocomposite sensor was prepared by elec-tropolymerisation of a mixture of aniline monomer and tungsten oxide on a graphene-modified glassycarbon electrode (GCE). The PANI/WO3/GR/GCE nanocomposite electrode was tested as a sensor for the determination of phenanthrene. The direct electro-oxidation behaviour of phenanthrene on thePANI/WO3/GR modified GCE was carefully investigated by cyclic voltammetry. The results indicated that the PANI/WO3/GR/GCE sensor was more sensitive to phenanthrene (with a dynamic linear range of 1.0 -6.0 pM and a detection limit of 0.123 pM.) than GCE, PANI/GCE or PANI/WO3/GCE. The sensor exhibited excellent reproducibility and long-term stability. The sensor exhibits lower detection sensitivity than the WHO permissible level of 1.12 nM phenanthrene in waste water.

Authors

Publication Details

Journal
Human Science Research Council SA
Published
2026-05-23
DOI
https://doi.org/10.14749/32386371
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Graphenated polyaniline-doped tungsten oxide nanocomposite sensor for real time determination of phenanthrene

Human Sciences Research Council
Human Science Research Council SA
Electrochemical sensors and biosensors
article

Graphenated polyaniline-doped tungsten oxide nanocomposite sensor for real time determination of phenanthrene

Human Sciences Research Council
article en

Abstract

A graphenated polyaniline/tungsten oxide (PANI/WO3/GR) nanocomposite sensor was prepared by elec-tropolymerisation of a mixture of aniline monomer and tungsten oxide on a graphene-modified glassycarbon electrode (GCE). The PANI/WO3/GR/GCE nanocomposite electrode was tested as a sensor for the determination of phenanthrene. The direct electro-oxidation behaviour of phenanthrene on thePANI/WO3/GR modified GCE was carefully investigated by cyclic voltammetry. The results indicated that the PANI/WO3/GR/GCE sensor was more sensitive to phenanthrene (with a dynamic linear range of 1.0 -6.0 pM and a detection limit of 0.123 pM.) than GCE, PANI/GCE or PANI/WO3/GCE. The sensor exhibited excellent reproducibility and long-term stability. The sensor exhibits lower detection sensitivity than the WHO permissible level of 1.12 nM phenanthrene in waste water.

Human Science Research Council SA
Clean water and sanitation
Openalex Percentile: Top 8%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.