Sensitive Quantification of the Ethylene Oxide Hemoglobin Adduct <i>N</i> -(2-Hydroxyethyl)- <scp>l</scp> -valine from Minimal Blood Volumes

-(2-hydroxyethyl)-l-valine (HE-V). However, current methods require large blood volumes, limiting small-animal exposure studies and reliable detection of endogenous background levels of HE-V. We optimized a highly sensitive analytical workflow including hemoglobin extraction from microliter-scale blood samples, HE-V purification, and targeted LC-MS/MS quantitative analysis. This workflow reliably quantifies endogenous HE-V levels of unexposed mice from only 50 μg of purified hemoglobin (10 μL of blood) and is demonstrated to detect significant HE-V increases at EtO exposures as low as 0.05 ppm. Our platform enables practical EtO biomonitoring in volume-constrained experimental and environmental settings.

Authors

Institutions

Publication Details

Journal
Chemical Research in Toxicology
Published
2026-05-23
DOI
https://doi.org/10.1021/acs.chemrestox.6c00200
Primary Topic
Hemoglobin structure and function
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitive Quantification of the Ethylene Oxide Hemoglobin Adduct N -(2-Hydroxyethyl)- l -valine from Minimal Blood Volumes

Jiahao Feng, Abby A. Li, Chih‐Wei Liu, Jingya Peng et al.
Chemical Research in Toxicology
Hemoglobin structure and function
article

Sensitive Quantification of the Ethylene Oxide Hemoglobin Adduct N -(2-Hydroxyethyl)- l -valine from Minimal Blood Volumes

Jiahao Feng, Abby A. Li, Chih‐Wei Liu, Jingya Peng, Xueying Wang, Haoduo Zhao, B. Bhaskar Gollapudi, Christopher Kirman, Kun Lu, James S. Bus
article en

Abstract

-(2-hydroxyethyl)-l-valine (HE-V). However, current methods require large blood volumes, limiting small-animal exposure studies and reliable detection of endogenous background levels of HE-V. We optimized a highly sensitive analytical workflow including hemoglobin extraction from microliter-scale blood samples, HE-V purification, and targeted LC-MS/MS quantitative analysis. This workflow reliably quantifies endogenous HE-V levels of unexposed mice from only 50 μg of purified hemoglobin (10 μL of blood) and is demonstrated to detect significant HE-V increases at EtO exposures as low as 0.05 ppm. Our platform enables practical EtO biomonitoring in volume-constrained experimental and environmental settings.

Chemical Research in Toxicology
University of North Carolina at Chapel Hill (US), Exponent (United States) (US), Dominion (United States) (US)
North Carolina State University, American Chemistry Council
Life in Land
Openalex Percentile: Top 7%
Hemoglobin structure and function
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.