Brachytherapy of skin cancer using a 90Sr/90Y beta-emitting source: design of a fixed geometry applicator

Beta radiation is a suitable candidate for treatment of skin cancer due to its rapid dose fall-off and better protection of normal tissues. This study aimed to design and propose a set of new fixed geometry applicators with a 90Sr/90Y beta source for treatment of superficial skin tumors. First, the 90Sr/90Y source of the Beta-Cath™ system supplied by Novoste Corporation was simulated with the MCNPX Monte Carlo code and validated using the proposed Task Group No. 60 dosimetric parameters. Then, considering parameters including the source-to-skin distance, treatment time, the shape and thickness of the flattening filter, the size and composition of the sources, and the dimensions of the field, the optimal applicator was selected in terms of flatness, symmetry, penumbra, leakage, and dose rate at different depths (1.0–3.0 mm). The mean difference in dose rate at the reference point, radial dose function, anisotropy function and two-dimensional dose rate compared to the corresponding published values was less than 3.0%. For a treatment depth of 3.0 mm, treatment times ranged from 6.97 to 10.22 min, the flatness values ​​of the optimal applicators in different sizes ranged from 3.36% to 14.94%, symmetry from 0.3% to 1.7%, and penumbra from 2.7 to 3.6 mm. Leakage within 1.0 mm of the applicator wall was less than 1% of the skin surface dose. This is the first study to evaluate the design of a fixed geometry applicator for a 90Sr/90Y beta-emitting source for skin cancer treatment. The designed applicator exhibited good performance in terms of dose distribution parameters such as flatness, symmetry, penumbra, and leakage.

Authors

Institutions

Publication Details

Journal
Radiation Oncology
Published
2026-05-23
DOI
https://doi.org/10.1186/s13014-026-02858-1
Primary Topic
Nonmelanoma Skin Cancer Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Brachytherapy of skin cancer using a 90Sr/90Y beta-emitting source: design of a fixed geometry applicator

Bagher Farhood, Nima Hamzian, Shahriyar Seraj, Mahdi Ghorbani
Radiation Oncology
Nonmelanoma Skin Cancer Studies
article

Brachytherapy of skin cancer using a 90Sr/90Y beta-emitting source: design of a fixed geometry applicator

Bagher Farhood, Nima Hamzian, Shahriyar Seraj, Mahdi Ghorbani
article en

Abstract

Beta radiation is a suitable candidate for treatment of skin cancer due to its rapid dose fall-off and better protection of normal tissues. This study aimed to design and propose a set of new fixed geometry applicators with a 90Sr/90Y beta source for treatment of superficial skin tumors. First, the 90Sr/90Y source of the Beta-Cath™ system supplied by Novoste Corporation was simulated with the MCNPX Monte Carlo code and validated using the proposed Task Group No. 60 dosimetric parameters. Then, considering parameters including the source-to-skin distance, treatment time, the shape and thickness of the flattening filter, the size and composition of the sources, and the dimensions of the field, the optimal applicator was selected in terms of flatness, symmetry, penumbra, leakage, and dose rate at different depths (1.0–3.0 mm). The mean difference in dose rate at the reference point, radial dose function, anisotropy function and two-dimensional dose rate compared to the corresponding published values was less than 3.0%. For a treatment depth of 3.0 mm, treatment times ranged from 6.97 to 10.22 min, the flatness values ​​of the optimal applicators in different sizes ranged from 3.36% to 14.94%, symmetry from 0.3% to 1.7%, and penumbra from 2.7 to 3.6 mm. Leakage within 1.0 mm of the applicator wall was less than 1% of the skin surface dose. This is the first study to evaluate the design of a fixed geometry applicator for a 90Sr/90Y beta-emitting source for skin cancer treatment. The designed applicator exhibited good performance in terms of dose distribution parameters such as flatness, symmetry, penumbra, and leakage.

Radiation Oncology
Kashan University of Medical Sciences (IR), Shahid Sadoughi University of Medical Sciences and Health Services (IR), Shahid Beheshti University of Medical Sciences (IR)
Good health and well-being
Openalex Percentile: Top 5%
Nonmelanoma Skin Cancer Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Brachytherapy of skin cancer using a 90Sr/90Y beta-emitting source: design of a fixed geometry applicator — Bagher Farhood, Nima Hamzian, et al. · Radiation Oncology (2026) | TGRS Research Map | TGRS