An Ex Vivo Model of Laser-Induced Microdamage to Study Tendon Repair.

model of extracellular matrix microdamage in live tendon explants that enables us to track both clearance of denatured collagen and closure of a microsized defect in the tendon matrix. The purpose of this study was to controllably induce varying levels of localized microdamage to the tendon explants and identify (1) if thresholds for repair exist and (2) whether repair mechanisms are dependent on initial damage size. We found that within 3 weeks, all tendon explants were able to clear damaged matrix to some extent regardless of the damage size. Interestingly, larger injuries resulted in a more robust rate of damaged matrix clearance in the later weeks, while smaller injuries exhibited a more consistent rate that led to full clearance in two explants. While all groups demonstrated some closure of the hole over the course of culture, only a small subset of explants with smaller initial hole sizes demonstrated nearly complete closure. Greater than 50% clearance of denatured collagen was typically associated with an accompanying closure of the defect, suggesting a strong relationship between clearance and closure. Overall, our work characterizes a novel laser-induced microdamage model, which will be a powerful asset for investigating mechanisms of damage accumulation and/or repair important to maintaining the mechanobiological function of the tendon, as well as identifying local tendon-specific factors that can be leveraged for therapeutics.Impact StatementIn this study, we developed a novel laser-based ablation system that produces tunable and reproducible micron-sized damage in live tendon explants. To our knowledge, this is the first direct demonstration that intrinsic cell-mediated responses can be sufficient to initiate tendon ECM repair in response to a localized microdamage injury. Moreover, this model provides a platform for direct visualization and analysis of local tissue repair, offering new opportunities to uncover mechanisms underlying microdamage accumulation and healing that maintain the mechanobiological function of the tendon, as well as to identify local tendon-specific factors that can be leveraged for therapeutics.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-05-23
DOI
https://doi.org/10.1177/19373341261449863
Primary Topic
Tendon Structure and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Ex Vivo Model of Laser-Induced Microdamage to Study Tendon Repair.

Anthony N. Aggouras, Brianne K. Connizzo, Irving J. Bigio, Jeroen Eyckmans et al.
PubMed
Tendon Structure and Treatment
article

An Ex Vivo Model of Laser-Induced Microdamage to Study Tendon Repair.

Anthony N. Aggouras, Brianne K. Connizzo, Irving J. Bigio, Jeroen Eyckmans, Mikayla Bradsby, Matthew T. M. Lim
article en

Abstract

model of extracellular matrix microdamage in live tendon explants that enables us to track both clearance of denatured collagen and closure of a microsized defect in the tendon matrix. The purpose of this study was to controllably induce varying levels of localized microdamage to the tendon explants and identify (1) if thresholds for repair exist and (2) whether repair mechanisms are dependent on initial damage size. We found that within 3 weeks, all tendon explants were able to clear damaged matrix to some extent regardless of the damage size. Interestingly, larger injuries resulted in a more robust rate of damaged matrix clearance in the later weeks, while smaller injuries exhibited a more consistent rate that led to full clearance in two explants. While all groups demonstrated some closure of the hole over the course of culture, only a small subset of explants with smaller initial hole sizes demonstrated nearly complete closure. Greater than 50% clearance of denatured collagen was typically associated with an accompanying closure of the defect, suggesting a strong relationship between clearance and closure. Overall, our work characterizes a novel laser-induced microdamage model, which will be a powerful asset for investigating mechanisms of damage accumulation and/or repair important to maintaining the mechanobiological function of the tendon, as well as identifying local tendon-specific factors that can be leveraged for therapeutics.Impact StatementIn this study, we developed a novel laser-based ablation system that produces tunable and reproducible micron-sized damage in live tendon explants. To our knowledge, this is the first direct demonstration that intrinsic cell-mediated responses can be sufficient to initiate tendon ECM repair in response to a localized microdamage injury. Moreover, this model provides a platform for direct visualization and analysis of local tissue repair, offering new opportunities to uncover mechanisms underlying microdamage accumulation and healing that maintain the mechanobiological function of the tendon, as well as to identify local tendon-specific factors that can be leveraged for therapeutics.

PubMed
Boston University (US)
Good health and well-being
Openalex Percentile: Top 5%
Tendon Structure and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.