Asymmetric tripolar nerve cuff electrode designs for optimizing anodal block of myelinated fibers

PURPOSE: Anodal block is a common mechanism used to generate unidirectional activation of myelinated nerve fibers. However, nerve block is often inconsistent and difficult to achieve. In this study, we used a computational model to investigate electrode cuff designs that can be exploited to enhance anodal block. METHODS: Asymmetric bipolar and tripolar nerve cuff electrodes were initially tested and validated in a rodent sciatic nerve model. A finite element model was implemented, with physical dimensions approximating a rat sciatic nerve implanted with a flat-interface nerve electrode. The McIntyre-Richardson-Grill model was used to predict the activation, block, and reactivation thresholds of myelinated fibers (diameter = 5.7 to 16 μm) as the stimulation amplitude was increased. In vivo experiments were performed using identical nerve cuff electrodes. The asymmetric electrode designs were subsequently investigated using a human-sized model of a nerve implanted with a cylindrical cuff electrode. Key design parameters included the electrode edge length (EEL), anodic contact width, inter-electrode distance, and current division between primary and secondary anodes. RESULTS: The rodent model reproduced blocking properties in both computational and in vivo studies, where maximum anodic block reached 88% and 75% of activated fibers, respectively. Simulations involving the human nerve model identified two critical design parameters that can markedly enhance anodal block. An optimal distal EEL (≤ 1 mm) enhanced the performance of bipolar stimulation (anodic block = 91%), whereas, optimizing the current ratio between the primary:secondary anodes (e.g., 6:4) enhanced nerve block in asymmetric tripolar electrodes (anodic block = 90%). CONCLUSION: This study presents a set of instructions for optimizing the anodal blocking properties of nerve cuff electrodes, where an asymmetric tripolar design with variable anodic current offers a novel method that can adjust for variability at the nerve electrode interface.

Authors

Institutions

Publication Details

Journal
BioMedical Engineering OnLine
Published
2026-05-23
DOI
https://doi.org/10.1186/s12938-026-01579-6
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Asymmetric tripolar nerve cuff electrode designs for optimizing anodal block of myelinated fibers

Ryan G. L. Koh, Paul B. Yoo, Daniel Tovbis, Rania Jeong
BioMedical Engineering OnLine
Neuroscience and Neural Engineering
article

Asymmetric tripolar nerve cuff electrode designs for optimizing anodal block of myelinated fibers

Ryan G. L. Koh, Paul B. Yoo, Daniel Tovbis, Rania Jeong
article en

Abstract

PURPOSE: Anodal block is a common mechanism used to generate unidirectional activation of myelinated nerve fibers. However, nerve block is often inconsistent and difficult to achieve. In this study, we used a computational model to investigate electrode cuff designs that can be exploited to enhance anodal block. METHODS: Asymmetric bipolar and tripolar nerve cuff electrodes were initially tested and validated in a rodent sciatic nerve model. A finite element model was implemented, with physical dimensions approximating a rat sciatic nerve implanted with a flat-interface nerve electrode. The McIntyre-Richardson-Grill model was used to predict the activation, block, and reactivation thresholds of myelinated fibers (diameter = 5.7 to 16 μm) as the stimulation amplitude was increased. In vivo experiments were performed using identical nerve cuff electrodes. The asymmetric electrode designs were subsequently investigated using a human-sized model of a nerve implanted with a cylindrical cuff electrode. Key design parameters included the electrode edge length (EEL), anodic contact width, inter-electrode distance, and current division between primary and secondary anodes. RESULTS: The rodent model reproduced blocking properties in both computational and in vivo studies, where maximum anodic block reached 88% and 75% of activated fibers, respectively. Simulations involving the human nerve model identified two critical design parameters that can markedly enhance anodal block. An optimal distal EEL (≤ 1 mm) enhanced the performance of bipolar stimulation (anodic block = 91%), whereas, optimizing the current ratio between the primary:secondary anodes (e.g., 6:4) enhanced nerve block in asymmetric tripolar electrodes (anodic block = 90%). CONCLUSION: This study presents a set of instructions for optimizing the anodal blocking properties of nerve cuff electrodes, where an asymmetric tripolar design with variable anodic current offers a novel method that can adjust for variability at the nerve electrode interface.

BioMedical Engineering OnLine
University of New Brunswick (CA), University of Toronto (CA), Toronto Rehabilitation Institute (CA), Rogers (United States) (US)
Canada Foundation for Innovation, Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 7%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.