Investigation of Fatigue Failure and Electrical Insulation Properties of Glass Fiber-Reinforced Epoxy Resin (EPGF) Composites Under Different Temperatures

This study investigates the influence of temperature on the bending properties, fatigue life, and breakdown voltage of glass fiber/epoxy composites (EPGF). The three-point bending tests were conducted at room temperature (RT) and 60 °C, and the bending fatigue tests were carried out under three displacement amplitudes (0.80, 0.75, 0.70). At the same time, fatigue life prediction was conducted using the Weibull distribution fitting, microscopic structure analysis by scanning electron microscopy (SEM), and breakdown voltage tests in accordance with the GB/T1408-2006 standard. The results show that at 60 °C, the ultimate bending strength and flexural modulus of EPGF decreased by 52.67% and 65.45%, respectively. At high displacement amplitudes (S = 0.80, 0.75), 60 °C leads to a sharp rise in data dispersion with the coefficient of variation (CV) surging by 1.56 and 2.32 times separately. S and temperature exert a significant synergistic degradation effect on fatigue life, and the two-parameter Weibull distribution (R2 > 0.85) can well characterize the fatigue life of EPGF. In terms of dielectric properties, 60 °C reduces the initial breakdown voltage of EPGF by 4.23% (p < 0.05). Fatigue damage causes a continuous drop in breakdown voltage. At RT with 80% damage, the reduction rate increases from 16.28% to 26.95% as S rises, showing a synergistic characteristic between amplitude and fatigue damage. Moreover, 60 °C only affects the initial breakdown voltage and has no significant effect on the fatigue-induced decrease in breakdown voltage. SEM observations indicate that 60 °C induces matrix cracking, fiber curling and interfacial debonding in EPGF. This study provides key experimental data and theoretical support for the fatigue life prediction and insulation performance evaluation of EPGF under different temperature fatigue conditions.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-05-22
DOI
https://doi.org/10.3390/en19112497
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Fatigue Failure and Electrical Insulation Properties of Glass Fiber-Reinforced Epoxy Resin (EPGF) Composites Under Different Temperatures

Bowen Xu, Chen Cao, Chenglu Wang, Jinghan Wang
Energies
High voltage insulation and dielectric phenomena
article

Investigation of Fatigue Failure and Electrical Insulation Properties of Glass Fiber-Reinforced Epoxy Resin (EPGF) Composites Under Different Temperatures

Bowen Xu, Chen Cao, Chenglu Wang, Jinghan Wang
article en

Abstract

This study investigates the influence of temperature on the bending properties, fatigue life, and breakdown voltage of glass fiber/epoxy composites (EPGF). The three-point bending tests were conducted at room temperature (RT) and 60 °C, and the bending fatigue tests were carried out under three displacement amplitudes (0.80, 0.75, 0.70). At the same time, fatigue life prediction was conducted using the Weibull distribution fitting, microscopic structure analysis by scanning electron microscopy (SEM), and breakdown voltage tests in accordance with the GB/T1408-2006 standard. The results show that at 60 °C, the ultimate bending strength and flexural modulus of EPGF decreased by 52.67% and 65.45%, respectively. At high displacement amplitudes (S = 0.80, 0.75), 60 °C leads to a sharp rise in data dispersion with the coefficient of variation (CV) surging by 1.56 and 2.32 times separately. S and temperature exert a significant synergistic degradation effect on fatigue life, and the two-parameter Weibull distribution (R2 > 0.85) can well characterize the fatigue life of EPGF. In terms of dielectric properties, 60 °C reduces the initial breakdown voltage of EPGF by 4.23% (p < 0.05). Fatigue damage causes a continuous drop in breakdown voltage. At RT with 80% damage, the reduction rate increases from 16.28% to 26.95% as S rises, showing a synergistic characteristic between amplitude and fatigue damage. Moreover, 60 °C only affects the initial breakdown voltage and has no significant effect on the fatigue-induced decrease in breakdown voltage. SEM observations indicate that 60 °C induces matrix cracking, fiber curling and interfacial debonding in EPGF. This study provides key experimental data and theoretical support for the fatigue life prediction and insulation performance evaluation of EPGF under different temperature fatigue conditions.

EnergiesVol. 19(11)
Shenyang University of Technology (CN), Xi’an Jiaotong-Liverpool University (CN)
Responsible consumption and production
Openalex Percentile: Top 11%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.