Magnetic field effects on positron range and image quality in PET/MR

This study investigates the influence of strong magnetic fields on the transport of positrons emitted by 18F and 68Ga and how these effects propagate to image quality metrics in tissue-equivalent phantoms relevant to PET/MR imaging. Monte Carlo simulations were performed using PENELOPE 2018, a well-established code for detailed low-energy radiation transport. Although electromagnetic fields are not directly implemented in its main code, the appropriate subroutines were combined to enable tracking of positrons up to annihilation in uniform magnetic fields of 0, 3, and 9 T. Simulations were carried out in four representative media (lung, soft tissue, water, and cortical bone) as well as in NEMA-like image quality phantoms used in a clinical PET/MR experimental study, to assess the impact of the magnetic fields on image quality and radiopharmaceutical quantification. The results demonstrate that positron range significantly affects recovery coefficients and spill-over ratios in NEMA-like image quality phantoms, particularly for high-energy positron emitters in low-density tissues, such as 68Ga in lung. Even under ideal Monte Carlo conditions, full signal recovery is never achieved, and recovery coefficients remain below unity due to the finite positron range. Spillover ratio results depend on the size of the volumes of interest in air cavities, as partial volume effects compromise quantitative accuracy. The magnetic field reduces these effects in the direction perpendicular to the field lines, leading to improved spatial resolution and quantitative accuracy in PET/MR. At 9 T, the dependence of positron range on tissue density is substantially reduced. These findings establish fundamental limits on image quality imposed by positron range in the presence of uniform magnetic fields, independent of detector technology or reconstruction algorithms. They provide a physical basis for the development of positron-range correction methods in PET/MR and offer quantitative insight into the potential benefits of ultra-high-field (9 T) PET/MR systems.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-05-22
DOI
https://doi.org/10.1088/2057-1976/ae71d4
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic field effects on positron range and image quality in PET/MR

Héctor Alva‐Sánchez, Mario Alberto González-Ramírez
Biomedical Physics & Engineering Express
Medical Imaging Techniques and Applications
article

Magnetic field effects on positron range and image quality in PET/MR

Héctor Alva‐Sánchez, Mario Alberto González-Ramírez
article en

Abstract

This study investigates the influence of strong magnetic fields on the transport of positrons emitted by 18F and 68Ga and how these effects propagate to image quality metrics in tissue-equivalent phantoms relevant to PET/MR imaging. Monte Carlo simulations were performed using PENELOPE 2018, a well-established code for detailed low-energy radiation transport. Although electromagnetic fields are not directly implemented in its main code, the appropriate subroutines were combined to enable tracking of positrons up to annihilation in uniform magnetic fields of 0, 3, and 9 T. Simulations were carried out in four representative media (lung, soft tissue, water, and cortical bone) as well as in NEMA-like image quality phantoms used in a clinical PET/MR experimental study, to assess the impact of the magnetic fields on image quality and radiopharmaceutical quantification. The results demonstrate that positron range significantly affects recovery coefficients and spill-over ratios in NEMA-like image quality phantoms, particularly for high-energy positron emitters in low-density tissues, such as 68Ga in lung. Even under ideal Monte Carlo conditions, full signal recovery is never achieved, and recovery coefficients remain below unity due to the finite positron range. Spillover ratio results depend on the size of the volumes of interest in air cavities, as partial volume effects compromise quantitative accuracy. The magnetic field reduces these effects in the direction perpendicular to the field lines, leading to improved spatial resolution and quantitative accuracy in PET/MR. At 9 T, the dependence of positron range on tissue density is substantially reduced. These findings establish fundamental limits on image quality imposed by positron range in the presence of uniform magnetic fields, independent of detector technology or reconstruction algorithms. They provide a physical basis for the development of positron-range correction methods in PET/MR and offer quantitative insight into the potential benefits of ultra-high-field (9 T) PET/MR systems.

Biomedical Physics & Engineering Express
Universidad Nacional Autónoma de México (MX)
European Commission, Universidad Nacional Autónoma de México, Dirección General de Asuntos del Personal Académico, Universidad Nacional Autónoma de México
Affordable and clean energy
Openalex Percentile: Top 5%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.