Evaluation of dosimetric consistency between pre- and postoperative CT-guided noncoplanar template-assisted ¹²⁵I seed implantation in recurrent and metastatic thoracic tumors: a retrospective study

Objective Recurrent and metastatic thoracic malignancies remain challenging to manage because of their proximity to vital structures and the impact of respiratory motion on dose accuracy. This retrospective study aimed to assess the dosimetric consistency between preoperative planning and postoperative verification in computed tomography (CT)-guided 3D-printed noncoplanar template (3DPNCT)-assisted ¹²⁵I seed implantation. Methods Clinical and dosimetric data from 32 patients who underwent 3DPNCT-assisted seed implantation were retrospectively reviewed. Preoperative treatment plans were compared with postoperative dose verification to evaluate deviations in key indices, including target coverage, dose conformity, and homogeneity. Statistical comparisons were performed using appropriate paired analyses, and agreement between planned and delivered doses was further evaluated through Bland–Altman analysis. Results The mean D90 decreased from 142.47 ± 28.90 Gy to 135.06 ± 31.66 Gy ( p = 0.022). The mean V100 decreased from 93.19 ± 14.74% to 91.48 ± 12.37% ( p = 0.441), and V150 from 73.81 ± 16.20% to 69.30 ± 17.61% ( p = 0.059). No significant differences were observed in V200, CI, or EI (all p > 0.05). The homogeneity index (HI) increased slightly from 0.222 ± 0.114 to 0.257 ± 0.130 ( p = 0.049). Conclusions CT-guided 3DPNCT-assisted ¹²⁵I seed implantation achieves robust dosimetric reproducibility and favorable plan accuracy in thoracic tumors. Despite minor deviations related to respiratory motion and intraoperative uncertainties, this approach provides a reliable and clinically feasible option for managing complex thoracic malignancies. Further prospective studies incorporating motion management and real-time adaptive planning are warranted to optimize its clinical application.

Authors

Institutions

Publication Details

Journal
PeerJ
Published
2026-05-22
DOI
https://doi.org/10.7717/peerj.21324
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of dosimetric consistency between pre- and postoperative CT-guided noncoplanar template-assisted ¹²⁵I seed implantation in recurrent and metastatic thoracic tumors: a retrospective study

Zhiwen Yan, Aihong Bi, Limin Luo, Wenming Zhan et al.
PeerJ
Advanced Radiotherapy Techniques
article

Evaluation of dosimetric consistency between pre- and postoperative CT-guided noncoplanar template-assisted ¹²⁵I seed implantation in recurrent and metastatic thoracic tumors: a retrospective study

Zhiwen Yan, Aihong Bi, Limin Luo, Wenming Zhan, Rong Wu, Qiu L, Y X Li, Qiang Li, Yinan Chen, Weijun Chen, Yinghao Zhang, Ziguo Zhang
article en

Abstract

Objective Recurrent and metastatic thoracic malignancies remain challenging to manage because of their proximity to vital structures and the impact of respiratory motion on dose accuracy. This retrospective study aimed to assess the dosimetric consistency between preoperative planning and postoperative verification in computed tomography (CT)-guided 3D-printed noncoplanar template (3DPNCT)-assisted ¹²⁵I seed implantation. Methods Clinical and dosimetric data from 32 patients who underwent 3DPNCT-assisted seed implantation were retrospectively reviewed. Preoperative treatment plans were compared with postoperative dose verification to evaluate deviations in key indices, including target coverage, dose conformity, and homogeneity. Statistical comparisons were performed using appropriate paired analyses, and agreement between planned and delivered doses was further evaluated through Bland–Altman analysis. Results The mean D90 decreased from 142.47 ± 28.90 Gy to 135.06 ± 31.66 Gy ( p = 0.022). The mean V100 decreased from 93.19 ± 14.74% to 91.48 ± 12.37% ( p = 0.441), and V150 from 73.81 ± 16.20% to 69.30 ± 17.61% ( p = 0.059). No significant differences were observed in V200, CI, or EI (all p > 0.05). The homogeneity index (HI) increased slightly from 0.222 ± 0.114 to 0.257 ± 0.130 ( p = 0.049). Conclusions CT-guided 3DPNCT-assisted ¹²⁵I seed implantation achieves robust dosimetric reproducibility and favorable plan accuracy in thoracic tumors. Despite minor deviations related to respiratory motion and intraoperative uncertainties, this approach provides a reliable and clinically feasible option for managing complex thoracic malignancies. Further prospective studies incorporating motion management and real-time adaptive planning are warranted to optimize its clinical application.

PeerJVol. 14
Zhejiang Chinese Medical University (CN), Southwest University of Science and Technology (CN), Yunnan Vocational College of Mechanical and Electrical Technology (CN), Zhejiang Provincial People's Hospital (CN), Hangzhou Hospital of Traditional Chinese Medicine (CN), Hangzhou Medical College (CN)
Medical and Health Research Project of Zhejiang Province
Good health and well-being
Openalex Percentile: Top 5%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.