Sub-second extracellular impedance measurement of epithelial cell monolayers using step excitations and time-domain analysis

Electrochemical impedance spectroscopy (EIS) is a versatile technique in epithelial biology, offering quantitative insights into barrier integrity, morphology, and apical-basolateral polarity non-invasively through measurements of transepithelial resistance (TER/TEER), capacitance (TEC), and membrane ratio (α). However, due to broad-spectrum frequency sweeps, EIS typically demands tens of seconds per measurement, limiting its applicability to faster biological phenomena. We present Time-domain Epithelial Impedance Measurement (TEIM), a method enabling sub-second extracellular impedance measurements of epithelial monolayers by combining step current excitations and time-domain voltage transient analysis while bypassing Fourier transforms. We experimentally demonstrate TEIM's ability to measure TER/TEER, TEC, α, and model-derived impedance spectrum every ∼0.3 s, which represents ∼100-fold time resolution improvement over EIS. TEIM's accuracy and precision were benchmarked against EIS using electrical circuits and human bronchial (16HBE) and colorectal (Caco-2) epithelial cell lines, yielding average errors for TER, TEC, and α ranging from 0.17-3.55%, 1.13-8.96%, and 0.59-26.35%, respectively. Applying TEIM to monitor Caco-2 responses to saponin revealed, for the first time, smoothly gated double-exponential transient TER and TEC dynamics too rapid to be adequately captured by EIS. Overall, TEIM offers a capable framework for probing rapid cellular electrophysiology, and offers a high-resolution alternative for dynamic assays in biological and pharmacological research.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-22
DOI
https://doi.org/10.1038/s41598-026-52673-7
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sub-second extracellular impedance measurement of epithelial cell monolayers using step excitations and time-domain analysis

Craig R. Forest, Athena Chien, Adrienne L. Watson, Benjamin Magondu et al.
Scientific Reports
Microfluidic and Bio-sensing Technologies
article

Sub-second extracellular impedance measurement of epithelial cell monolayers using step excitations and time-domain analysis

Craig R. Forest, Athena Chien, Adrienne L. Watson, Benjamin Magondu, Rongming Guo, Jake Hawks, Bob Lewis, Chris Hatcher, Xavier Acevedo, Bo Gyeong Yang
article en

Abstract

Electrochemical impedance spectroscopy (EIS) is a versatile technique in epithelial biology, offering quantitative insights into barrier integrity, morphology, and apical-basolateral polarity non-invasively through measurements of transepithelial resistance (TER/TEER), capacitance (TEC), and membrane ratio (α). However, due to broad-spectrum frequency sweeps, EIS typically demands tens of seconds per measurement, limiting its applicability to faster biological phenomena. We present Time-domain Epithelial Impedance Measurement (TEIM), a method enabling sub-second extracellular impedance measurements of epithelial monolayers by combining step current excitations and time-domain voltage transient analysis while bypassing Fourier transforms. We experimentally demonstrate TEIM's ability to measure TER/TEER, TEC, α, and model-derived impedance spectrum every ∼0.3 s, which represents ∼100-fold time resolution improvement over EIS. TEIM's accuracy and precision were benchmarked against EIS using electrical circuits and human bronchial (16HBE) and colorectal (Caco-2) epithelial cell lines, yielding average errors for TER, TEC, and α ranging from 0.17-3.55%, 1.13-8.96%, and 0.59-26.35%, respectively. Applying TEIM to monitor Caco-2 responses to saponin revealed, for the first time, smoothly gated double-exponential transient TER and TEC dynamics too rapid to be adequately captured by EIS. Overall, TEIM offers a capable framework for probing rapid cellular electrophysiology, and offers a high-resolution alternative for dynamic assays in biological and pharmacological research.

Scientific Reports
Georgia Institute of Technology (US), The Wallace H. Coulter Department of Biomedical Engineering (US), World Precision Instruments (United States) (US)
Institute for Bioengineering and Biosciences, National Institutes of Health, National Institute on Aging, National Institute on Drug Abuse, National Eye Institute, National Institute of Neurological Disorders and Stroke
Openalex Percentile: Top 9%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.