Hybrid motion–measurement control and traceable HMI for a 3-PSP manipulator

Purpose This study aims to present and validate a hybrid motion–measurement control architecture and a traceability-oriented human–machine interface (HMI) for a three-DOF 3-prismatic–spherical–prismatic (3-PSP) parallel manipulator configured as a micro-coordinate measuring machine (CMM), improving stability, reproducibility and metrological traceability. Design/methodology/approach Control software integrates LabVIEW with embedded Python for forward/inverse kinematics model. Closed-loop iterative positioning reconciles IKM setpoints with DKM estimates prior to contact; a stop-on-trigger routine then captures coordinates without disturbing contact. Real-time laser-sensor fusion provides pose estimation; deterministic logging records setpoints, sensor snapshots, triggers and operator actions. Performance is benchmarked against a calibrated industrial CMM on a 25-point data set. Findings Mean 3D error is sub-millimetre (≈0.66 mm) with sub-micrometre repeatability under controlled approaches. Bland–Altman analysis shows a small bias (0.317 mm) and negligible proportional bias. Absolute accuracy is mainly limited by geometric calibration and workspace sensitivity; the hybrid logic yields stable convergence and consistent capture. Research limitations/implications Tests cover a translational 3-DOF platform in lab conditions without thermal compensation or geometric error maps. Practical implications The modular LabVIEW–Python framework and traceability-first logging are readily transferable to other PKM/CMM platforms, aiding ISO-aligned auditability and lowering integration cost for SMEs. Originality/value This study provides a software-centric, validated template that couples deterministic hybrid control with comprehensive provenance to enhance reproducibility in PKM-based micro-metrology.

Authors

Institutions

Publication Details

Journal
Industrial Robot the international journal of robotics research and application
Published
2026-05-23
DOI
https://doi.org/10.1108/ir-10-2025-0358
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid motion–measurement control and traceable HMI for a 3-PSP manipulator

Ali Rugbani, Abdulhakim Agll
Industrial Robot the international journal of robotics research and application
Advanced Measurement and Metrology Techniques
article

Hybrid motion–measurement control and traceable HMI for a 3-PSP manipulator

Ali Rugbani, Abdulhakim Agll
article en

Abstract

Purpose This study aims to present and validate a hybrid motion–measurement control architecture and a traceability-oriented human–machine interface (HMI) for a three-DOF 3-prismatic–spherical–prismatic (3-PSP) parallel manipulator configured as a micro-coordinate measuring machine (CMM), improving stability, reproducibility and metrological traceability. Design/methodology/approach Control software integrates LabVIEW with embedded Python for forward/inverse kinematics model. Closed-loop iterative positioning reconciles IKM setpoints with DKM estimates prior to contact; a stop-on-trigger routine then captures coordinates without disturbing contact. Real-time laser-sensor fusion provides pose estimation; deterministic logging records setpoints, sensor snapshots, triggers and operator actions. Performance is benchmarked against a calibrated industrial CMM on a 25-point data set. Findings Mean 3D error is sub-millimetre (≈0.66 mm) with sub-micrometre repeatability under controlled approaches. Bland–Altman analysis shows a small bias (0.317 mm) and negligible proportional bias. Absolute accuracy is mainly limited by geometric calibration and workspace sensitivity; the hybrid logic yields stable convergence and consistent capture. Research limitations/implications Tests cover a translational 3-DOF platform in lab conditions without thermal compensation or geometric error maps. Practical implications The modular LabVIEW–Python framework and traceability-first logging are readily transferable to other PKM/CMM platforms, aiding ISO-aligned auditability and lowering integration cost for SMEs. Originality/value This study provides a software-centric, validated template that couples deterministic hybrid control with comprehensive provenance to enhance reproducibility in PKM-based micro-metrology.

Industrial Robot the international journal of robotics research and application
Cape Peninsula University of Technology (ZA), University of Tripoli (LY)
Openalex Percentile: Top 10%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.