Mass-Based Replacement of Natural Coarse Aggregate with Electric Arc Furnace Slag Aggregate in Ordinary Portland Cement Concrete

This study investigates the effect of mass-based replacement of natural coarse aggregate with electric arc furnace (EAF) slag on the performance of ordinary Portland cement (OPC) concrete. Replacement levels of 0%, 30%, 50%, and 100% were examined, with particular attention to the volumetric changes induced by the higher density of EAF slag, which leads to an increase in paste volume. Fresh, mechanical, durability-related, and microstructural properties were evaluated. Results show a continuous reduction in workability with increasing slag content, despite the increase in paste volume, indicating the dominant influence of aggregate morphology on rheological behavior. Mechanical performance exhibited a non-linear response. Within the tested series, the 50% replacement mixture showed the highest mean compressive and splitting tensile strengths; however, the compressive strength difference relative to the control mixture remained small and within typical experimental scatter. In contrast, water absorption decreased progressively, reflecting improved matrix densification. However, this densification did not translate into enhanced mechanical performance, highlighting a decoupling between durability-related indicators and strength. A screening-level CO2 assessment further showed that reductions in aggregate-related emissions were offset by increased cement content associated with mass-based replacement. The results emphasize the importance of considering volumetric effects when interpreting the behavior and sustainability of slag-based concrete. Note: all strength comparisons are based on mean values from three-specimen sets without formal statistical testing and should be regarded as exploratory observations.

Authors

Institutions

Publication Details

Journal
Construction Materials
Published
2026-05-22
DOI
https://doi.org/10.3390/constrmater6030031
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mass-Based Replacement of Natural Coarse Aggregate with Electric Arc Furnace Slag Aggregate in Ordinary Portland Cement Concrete

Christina El Sawda, Mohamad Ali-Ahmad, Malak Sughayer, Sarah AlMajed et al.
Construction Materials
Concrete and Cement Materials Research
article

Mass-Based Replacement of Natural Coarse Aggregate with Electric Arc Furnace Slag Aggregate in Ordinary Portland Cement Concrete

Christina El Sawda, Mohamad Ali-Ahmad, Malak Sughayer, Sarah AlMajed, Nourah AlZuabi, Nourah AlKhaldi, Amenah AlFailakawi
article en

Abstract

This study investigates the effect of mass-based replacement of natural coarse aggregate with electric arc furnace (EAF) slag on the performance of ordinary Portland cement (OPC) concrete. Replacement levels of 0%, 30%, 50%, and 100% were examined, with particular attention to the volumetric changes induced by the higher density of EAF slag, which leads to an increase in paste volume. Fresh, mechanical, durability-related, and microstructural properties were evaluated. Results show a continuous reduction in workability with increasing slag content, despite the increase in paste volume, indicating the dominant influence of aggregate morphology on rheological behavior. Mechanical performance exhibited a non-linear response. Within the tested series, the 50% replacement mixture showed the highest mean compressive and splitting tensile strengths; however, the compressive strength difference relative to the control mixture remained small and within typical experimental scatter. In contrast, water absorption decreased progressively, reflecting improved matrix densification. However, this densification did not translate into enhanced mechanical performance, highlighting a decoupling between durability-related indicators and strength. A screening-level CO2 assessment further showed that reductions in aggregate-related emissions were offset by increased cement content associated with mass-based replacement. The results emphasize the importance of considering volumetric effects when interpreting the behavior and sustainability of slag-based concrete. Note: all strength comparisons are based on mean values from three-specimen sets without formal statistical testing and should be regarded as exploratory observations.

Construction MaterialsVol. 6(3)
American University of the Middle East (KW)
Responsible consumption and production
Openalex Percentile: Top 8%
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.