Independent and Incremental Value of Breast Mass Orientation Angle in Ultrasound‐Based Malignancy Prediction

OBJECTIVES: Orientation of breast masses on ultrasonography is a well-recognized feature for differentiating benign from malignant lesions. Recent studies suggest that quantitative assessment of the orientation angle may improve diagnostic discrimination. This study aimed to evaluate the diagnostic performance of the orientation angle in a real-world cohort and to determine its incremental value when integrated with established clinical and sonographic predictors. METHODS: This retrospective study included 502 biopsy-proven breast lesions evaluated with ultrasound between 2019 and 2025. The orientation angle was defined as the acute angle between the longest axis of the lesion and the skin surface measured on transverse images. Inter-reader reliability was assessed using intraclass correlation coefficients (ICCs). Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis. Multivariable logistic regression models were constructed with and without the orientation angle to assess independent predictors of malignancy and incremental model performance. RESULTS: Of the 502 lesions, 258 (51.4%) were malignant. Measurement reliability was excellent, with ICC values exceeding 0.96. Malignant lesions demonstrated significantly larger orientation angles than benign lesions and showed a stepwise increase across Breast Imaging Reporting and Data System categories. An optimal cut-off value of 25.3° yielded an AUC of 0.72, specificity of 90.2%, and a positive likelihood ratio of 4.66. In multivariable analysis, orientation angle remained independently associated with malignancy (odds ratio 1.03 per degree increase; p < .001). CONCLUSION: Quantitative orientation angle is a reproducible and independent predictor of breast malignancy and provides incremental diagnostic value beyond conventional ultrasound descriptors, supporting its role as a complementary imaging biomarker in breast ultrasound assessment.

Authors

Institutions

Publication Details

Journal
Journal of Ultrasound in Medicine
Published
2026-05-22
DOI
https://doi.org/10.1002/jum.70310
Primary Topic
Breast Lesions and Carcinomas
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Independent and Incremental Value of Breast Mass Orientation Angle in Ultrasound‐Based Malignancy Prediction

Edwin Sanjaya, Gilbert Sterling Octavius, Vera Nevyta Tarigan, Fajar Lamhot Gultom et al.
Journal of Ultrasound in Medicine
Breast Lesions and Carcinomas
article

Independent and Incremental Value of Breast Mass Orientation Angle in Ultrasound‐Based Malignancy Prediction

Edwin Sanjaya, Gilbert Sterling Octavius, Vera Nevyta Tarigan, Fajar Lamhot Gultom, Callistus Bruce Henfry Sulay, Nungky Kusumaningtyas, Malvin Chandra, Evan Nugroho, Nina ISH Supit
article en

Abstract

OBJECTIVES: Orientation of breast masses on ultrasonography is a well-recognized feature for differentiating benign from malignant lesions. Recent studies suggest that quantitative assessment of the orientation angle may improve diagnostic discrimination. This study aimed to evaluate the diagnostic performance of the orientation angle in a real-world cohort and to determine its incremental value when integrated with established clinical and sonographic predictors. METHODS: This retrospective study included 502 biopsy-proven breast lesions evaluated with ultrasound between 2019 and 2025. The orientation angle was defined as the acute angle between the longest axis of the lesion and the skin surface measured on transverse images. Inter-reader reliability was assessed using intraclass correlation coefficients (ICCs). Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis. Multivariable logistic regression models were constructed with and without the orientation angle to assess independent predictors of malignancy and incremental model performance. RESULTS: Of the 502 lesions, 258 (51.4%) were malignant. Measurement reliability was excellent, with ICC values exceeding 0.96. Malignant lesions demonstrated significantly larger orientation angles than benign lesions and showed a stepwise increase across Breast Imaging Reporting and Data System categories. An optimal cut-off value of 25.3° yielded an AUC of 0.72, specificity of 90.2%, and a positive likelihood ratio of 4.66. In multivariable analysis, orientation angle remained independently associated with malignancy (odds ratio 1.03 per degree increase; p < .001). CONCLUSION: Quantitative orientation angle is a reproducible and independent predictor of breast malignancy and provides incremental diagnostic value beyond conventional ultrasound descriptors, supporting its role as a complementary imaging biomarker in breast ultrasound assessment.

Journal of Ultrasound in Medicine
Universitas Kristen Indonesia (ID), Pelita Harapan University (ID), Siloam Eye Hospital (KR)
Gender equality
Openalex Percentile: Top 5%
Breast Lesions and Carcinomas
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.