Pacing‐Induced Cardiomyopathy in Leadless and Transvenous Pacemakers: A Meta‐Analysis and Meta‐Regression

ABSTRACT Background Leadless pacemakers have been developed to reduce complications associated with transvenous systems; however, their impact on pacing‐induced cardiomyopathy (PICM) remains uncertain. This study aimed to evaluate the prevalence of PICM following leadless pacing, compared PICM risk with transvenous pacing, and assessed cardiac resynchronization therapy (CRT) upgrade. Methods This systematic review and meta‐analysis followed PRISMA guidelines. PubMed, Scopus, and ScienceDirect were searched up to January 2026. Studies reporting PICM following leadless pacing or comparing leadless and transvenous systems were included. Random‐effects models estimated pooled prevalence and risk ratios (RRs), and meta‐regression explored potential modifiers. Results Eight studies comprising 3224 patients with leadless pacing were included. The pooled prevalence of PICM following leadless pacing was 13% (95%CI: 4%–23%; I 2 = 92%). In comparative analysis (5 studies; n = 6025), the risk of PICM was similar between leadless and transvenous pacing (RR 1.00; 95%CI: 0.77–1.29; I 2 = 52%). Leadless pacing was associated with a lower observed rate of CRT upgrade (RR 0.56; 95%CI: 0.48–0.66; I 2 = 42%), although this finding should be interpreted cautiously because it may reflect patient selection, procedural factors, and differing thresholds for CRT upgrade. Meta‐regression identified baseline heart failure (HF) as a significant predictor of PICM ( p < 0.0001). Conclusion Leadless pacemakers demonstrate a non‐inferior risk of PICM and similar safety profiles to transvenous systems, while a lower observed rate of CRT upgrade. Future studies should standardize PICM definitions and improve reporting of pacing burden, ventricular function, and patient‐level outcomes.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-05-22
DOI
https://doi.org/10.1111/pace.70299
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pacing‐Induced Cardiomyopathy in Leadless and Transvenous Pacemakers: A Meta‐Analysis and Meta‐Regression

Alberta Claudia Undarsa, Antonia Anna Lukito, Raymond Pranata, Christopher Daniel Tristan et al.
Pacing and Clinical Electrophysiology
Cardiac pacing and defibrillation studies
article

Pacing‐Induced Cardiomyopathy in Leadless and Transvenous Pacemakers: A Meta‐Analysis and Meta‐Regression

Alberta Claudia Undarsa, Antonia Anna Lukito, Raymond Pranata, Christopher Daniel Tristan, Artha Maressa Theodora Simanjuntak, Frengki Prabowo Saputro Wijayanto
article en

Abstract

ABSTRACT Background Leadless pacemakers have been developed to reduce complications associated with transvenous systems; however, their impact on pacing‐induced cardiomyopathy (PICM) remains uncertain. This study aimed to evaluate the prevalence of PICM following leadless pacing, compared PICM risk with transvenous pacing, and assessed cardiac resynchronization therapy (CRT) upgrade. Methods This systematic review and meta‐analysis followed PRISMA guidelines. PubMed, Scopus, and ScienceDirect were searched up to January 2026. Studies reporting PICM following leadless pacing or comparing leadless and transvenous systems were included. Random‐effects models estimated pooled prevalence and risk ratios (RRs), and meta‐regression explored potential modifiers. Results Eight studies comprising 3224 patients with leadless pacing were included. The pooled prevalence of PICM following leadless pacing was 13% (95%CI: 4%–23%; I 2 = 92%). In comparative analysis (5 studies; n = 6025), the risk of PICM was similar between leadless and transvenous pacing (RR 1.00; 95%CI: 0.77–1.29; I 2 = 52%). Leadless pacing was associated with a lower observed rate of CRT upgrade (RR 0.56; 95%CI: 0.48–0.66; I 2 = 42%), although this finding should be interpreted cautiously because it may reflect patient selection, procedural factors, and differing thresholds for CRT upgrade. Meta‐regression identified baseline heart failure (HF) as a significant predictor of PICM ( p < 0.0001). Conclusion Leadless pacemakers demonstrate a non‐inferior risk of PICM and similar safety profiles to transvenous systems, while a lower observed rate of CRT upgrade. Future studies should standardize PICM definitions and improve reporting of pacing burden, ventricular function, and patient‐level outcomes.

Pacing and Clinical Electrophysiology
Pelita Harapan University (ID), Sebelas Maret University (ID), Universitas Gadjah Mada (ID), Universitas Muhammadiyah Cirebon (ID), Siloam Eye Hospital (KR)
Good health and well-being
Openalex Percentile: Top 6%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.