Improving the surface quality of “M” shape-link 316L stent by electrochemical polishing and investigating its mechanical properties

Additive manufacturing of metal stents (such as selective laser melting technology) may result in a relatively high surface roughness, which significantly affects the mechanical properties. To address the surface quality issue, this study employed electrochemical polishing technology to reduce the surface roughness of "M" shape-link 316L stent manufactured by selective laser melting technology, and evaluated the mechanical properties. The results showed that electrochemical polishing effectively removed the residual powder particles adhering to the surface of stent and the irregular surface protrusions formed during the manufacturing process, thereby reducing the surface roughness of 316L stents to less than 5 µm. Electrochemical polishing decreased the radial force of stents from 31.68 N to 19.71 N, but improved the axial compliance and flexibility. Its bending stiffness (10 N/mm) was reduced by 16 N/mm compared to 26 N/mm before polishing. The maximum load at the maximum deformation of 2.5 mm decreased by 4.8 N, thereby improving the compliance. Additionally, the maximum bending force (5.8 N) decreased by only 8.37 N, indicating that its resistance to bending fracture was sufficiently strong. Meanwhile, electrochemical polishing did not reduce the fatigue life of stents. After subjecting the polished stent to 1 × 10⁶ cycles of accelerated cyclic loading, the stent still retained its initial structural integrity, while both its peak pressure and overall pressure decreased, the specific reduction was only 12.5%. In conclusion, after electrochemical polishing, although a certain degree of stent rigidity was sacrificed, good flexibility and potential long-term implant durability were achieved.

Authors

Institutions

Publication Details

Journal
Surface Science and Technology
Published
2026-05-22
DOI
https://doi.org/10.1007/s44251-026-00145-5
Primary Topic
Advanced Surface Polishing Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving the surface quality of “M” shape-link 316L stent by electrochemical polishing and investigating its mechanical properties

Xiaoman Guo, Hezong Li, Chen Pan, Luhan Li
Surface Science and Technology
Advanced Surface Polishing Techniques
article

Improving the surface quality of “M” shape-link 316L stent by electrochemical polishing and investigating its mechanical properties

Xiaoman Guo, Hezong Li, Chen Pan, Luhan Li
article en

Abstract

Additive manufacturing of metal stents (such as selective laser melting technology) may result in a relatively high surface roughness, which significantly affects the mechanical properties. To address the surface quality issue, this study employed electrochemical polishing technology to reduce the surface roughness of "M" shape-link 316L stent manufactured by selective laser melting technology, and evaluated the mechanical properties. The results showed that electrochemical polishing effectively removed the residual powder particles adhering to the surface of stent and the irregular surface protrusions formed during the manufacturing process, thereby reducing the surface roughness of 316L stents to less than 5 µm. Electrochemical polishing decreased the radial force of stents from 31.68 N to 19.71 N, but improved the axial compliance and flexibility. Its bending stiffness (10 N/mm) was reduced by 16 N/mm compared to 26 N/mm before polishing. The maximum load at the maximum deformation of 2.5 mm decreased by 4.8 N, thereby improving the compliance. Additionally, the maximum bending force (5.8 N) decreased by only 8.37 N, indicating that its resistance to bending fracture was sufficiently strong. Meanwhile, electrochemical polishing did not reduce the fatigue life of stents. After subjecting the polished stent to 1 × 10⁶ cycles of accelerated cyclic loading, the stent still retained its initial structural integrity, while both its peak pressure and overall pressure decreased, the specific reduction was only 12.5%. In conclusion, after electrochemical polishing, although a certain degree of stent rigidity was sacrificed, good flexibility and potential long-term implant durability were achieved.

Surface Science and TechnologyVol. 4(1)
Hebei University of Engineering (CN), Handan College (CN)
Department of Education of Hebei Province
Openalex Percentile: Top 9%
Advanced Surface Polishing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.