A complete-electrode-model-based forward approach for transcranial temporal interference stimulation with linearization: A numerical simulation study

Background and Objective: Transcranial temporal interference stimulation (tTIS) is a promising non-invasive brain stimulation technique in which interference between electrical current fields extends the possibilities of electrical brain stimulation. This study aims to establish and evaluate the complete electrode model (CEM), a set of boundary conditions incorporating electrode impedance and contact patch, as a forward simulation technique for tTIS and investigate linearized CEM as a surrogate. Methods: The electric potential distribution in the head was simulated using the finite element method (FEM) combined with the CEM. A frequency-dependent lead field formulation and its linearization with respect to electrode impedance were implemented to reflect the capacitive properties of electrode interfaces. The simulations were conducted in a realistic multi-compartment head model, where the accuracy of the surrogate was evaluated against the full nonlinear model across two different changes in contact impedance from the initial R c = 270 Ω to R c ∈ { 1270 , 5270 } Ω . Results: The CEM-based forward simulation successfully reproduced the volumetric stimulating fields induced by tTIS. The linearized CEM model closely matched the full nonlinear model within a predefined peak signal-to-noise ratio (PSNR) threshold for relative error. Both models exhibited the highest sensitivity near the focal region of tTIS. Conclusion: The results demonstrate that linearization with respect to frequency can yield a computationally efficient approximation of the lead field, retaining sufficient accuracy within a practical PSNR threshold. The surrogate captures key sensitivity characteristics of the full model, particularly near the focal region, highlighting its potential for tasks where frequent updates of stimulation parameters are required.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-05-22
DOI
https://doi.org/10.1016/j.bspc.2026.110624
Primary Topic
Transcranial Magnetic Stimulation Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A complete-electrode-model-based forward approach for transcranial temporal interference stimulation with linearization: A numerical simulation study

Santtu Söderholm, Sampsa Pursiainen, Maryam Samavaki
Biomedical Signal Processing and Control
Transcranial Magnetic Stimulation Studies
article

A complete-electrode-model-based forward approach for transcranial temporal interference stimulation with linearization: A numerical simulation study

Santtu Söderholm, Sampsa Pursiainen, Maryam Samavaki
article en

Abstract

Background and Objective: Transcranial temporal interference stimulation (tTIS) is a promising non-invasive brain stimulation technique in which interference between electrical current fields extends the possibilities of electrical brain stimulation. This study aims to establish and evaluate the complete electrode model (CEM), a set of boundary conditions incorporating electrode impedance and contact patch, as a forward simulation technique for tTIS and investigate linearized CEM as a surrogate. Methods: The electric potential distribution in the head was simulated using the finite element method (FEM) combined with the CEM. A frequency-dependent lead field formulation and its linearization with respect to electrode impedance were implemented to reflect the capacitive properties of electrode interfaces. The simulations were conducted in a realistic multi-compartment head model, where the accuracy of the surrogate was evaluated against the full nonlinear model across two different changes in contact impedance from the initial R c = 270 Ω to R c ∈ { 1270 , 5270 } Ω . Results: The CEM-based forward simulation successfully reproduced the volumetric stimulating fields induced by tTIS. The linearized CEM model closely matched the full nonlinear model within a predefined peak signal-to-noise ratio (PSNR) threshold for relative error. Both models exhibited the highest sensitivity near the focal region of tTIS. Conclusion: The results demonstrate that linearization with respect to frequency can yield a computationally efficient approximation of the lead field, retaining sufficient accuracy within a practical PSNR threshold. The surrogate captures key sensitivity characteristics of the full model, particularly near the focal region, highlighting its potential for tasks where frequent updates of stimulation parameters are required.

Biomedical Signal Processing and ControlVol. 124
Tampere University of Applied Sciences (FI), Illinois College (US), University of Eastern Finland (FI), University of Illinois Chicago (US), Finland University (FI), Tampere University (FI)
Academy of Finland
Openalex Percentile: Top 6%
Transcranial Magnetic Stimulation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.