Capacitive Insect Sensing Under a Single Dual-Arc Geometry: A Laboratory Benchmark of Four CDC Architectures

Capacitive sensing offers a low-power, non-optical route for automated insect monitoring, but architecture-level benchmarking under shared geometry remains limited. Rather than presenting a general framework, this study proposed a configuration-specific laboratory benchmark comparing four sigma-delta and charge-transfers in a 6 mm dual-arc conduit at 25 °C, targeting six adult terrestrial arthropod species spanning a 25-fold range of the body cross-sectional area. Static measurements showed a strong linear relationship between ΔC_static and body cross-sectional area (17.96 fF/mm2, r = 0.995), supporting first-pass conduit sizing and detectability screening. In contrast, transit amplitudes were not monotonic with body size because posture, motion, and gap occupancy affected waveform shape. Under chamber conditions, static sensitivity degraded by less than 3.2% across all architectures from RH 40% to 80%. However, under the deployment-oriented noise model, SNR_FR degradation was substantially higher for charge-transfer devices (64.8–66.8%) than for Σ–Δ devices (≤35.5%), because the composite noise floor amplifies the effect of humidity-induced baseline drift. These results generated a conduit-specific reference dataset for preliminary capacitance-to-digital converter (CDC) selection within the tested 6 mm dual-arc geometry. In addition, the experimental validation focused on laboratory baseline noise characterization, long-term drift, and trap-integrated testing in temperature-controlled environments and natural-locomotion trials, providing critical information on configuration-specific architectures and body-size-scaling reference. This study serves as an initial step toward real-world capacitive insect sensing. Future studies will investigate additional conduit geometries and insect species to improve the robustness of the proposed framework.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-05-22
DOI
https://doi.org/10.3390/s26113306
Primary Topic
Insect Pheromone Research and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Capacitive Insect Sensing Under a Single Dual-Arc Geometry: A Laboratory Benchmark of Four CDC Architectures

Joe‐Air Jiang, Sen-Miao Chen, Yu-Bing Huang, Jen-Cheng Wang
Sensors
Insect Pheromone Research and Control
article

Capacitive Insect Sensing Under a Single Dual-Arc Geometry: A Laboratory Benchmark of Four CDC Architectures

Joe‐Air Jiang, Sen-Miao Chen, Yu-Bing Huang, Jen-Cheng Wang
article en

Abstract

Capacitive sensing offers a low-power, non-optical route for automated insect monitoring, but architecture-level benchmarking under shared geometry remains limited. Rather than presenting a general framework, this study proposed a configuration-specific laboratory benchmark comparing four sigma-delta and charge-transfers in a 6 mm dual-arc conduit at 25 °C, targeting six adult terrestrial arthropod species spanning a 25-fold range of the body cross-sectional area. Static measurements showed a strong linear relationship between ΔC_static and body cross-sectional area (17.96 fF/mm2, r = 0.995), supporting first-pass conduit sizing and detectability screening. In contrast, transit amplitudes were not monotonic with body size because posture, motion, and gap occupancy affected waveform shape. Under chamber conditions, static sensitivity degraded by less than 3.2% across all architectures from RH 40% to 80%. However, under the deployment-oriented noise model, SNR_FR degradation was substantially higher for charge-transfer devices (64.8–66.8%) than for Σ–Δ devices (≤35.5%), because the composite noise floor amplifies the effect of humidity-induced baseline drift. These results generated a conduit-specific reference dataset for preliminary capacitance-to-digital converter (CDC) selection within the tested 6 mm dual-arc geometry. In addition, the experimental validation focused on laboratory baseline noise characterization, long-term drift, and trap-integrated testing in temperature-controlled environments and natural-locomotion trials, providing critical information on configuration-specific architectures and body-size-scaling reference. This study serves as an initial step toward real-world capacitive insect sensing. Future studies will investigate additional conduit geometries and insect species to improve the robustness of the proposed framework.

SensorsVol. 26(11)
National Taiwan University (TW), China Medical University (TW), China Medical University Hospital (TW), National Taipei University of Education (TW)
Openalex Percentile: Top 6%
Insect Pheromone Research and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.