Anti-focus driving signals to mitigate bone heating during focused ultrasound ablation of uterine fibroids with phased arrays

OBJECTIVE: During magnetic resonance-guided focused ultrasound (MRgFUS) treatment of uterine fibroids, ablating tissue near the spine is challenging as unwanted far-field bone heating can cause pain and potentially injure nearby nerves. This study investigates an anti-focus (AF) scheme for minimizing bone heating when targeting fibroid tissue in proximity to the spine.&#xD;Approach: Acoustic and thermal simulations were conducted using 3D MRI-derived anatomical models from ten patients who underwent MRgFUS for uterine fibroids using a low-frequency (0.5 MHz) 6144-element flat fully-populated modular phased array during a clinical trial (NCT03323905). AF points were distributed over patient spine surfaces with varying densities, transducer array element-wise phase and amplitude controls were obtained via Tikhonov regularization, and the resulting temperature fields were compared to those obtained via both conventional focusing (CF) and a transducer module partial blocking (PB) approach developed to mitigate far-field bone heating [Goudarzi et al., Med. Phys. 51(12):8670-87 (2024)]. Optimal regularization parameter values were chosen to maximize the focal-to-bone heating ratio (ΔTratio) while maintaining focal integrity.&#xD;Results: For high point densities (0.25 AF/mm²), AF driving signals provided significant improvements in ΔTratio compared to CF (fold improvement: 13 ± 16, p = 0.0009) and the optimal PB approach (fold improvement: 11 ± 11, p = 0.0009), at the cost of more diffuse focusing (focal heating volumes increased 77% ± 23% vs. CF; 50% ± 33% vs. PB; p < 0.0001) and thus requiring higher acoustic power levels to maintain focal heating (increased 73% ± 19% vs. CF; 15 ± 20% vs. PB; p < 0.0001). Soft-tissue aberration corrections improved focal targeting accuracy and reduced acoustic power demands, complementing the AF strategy.&#xD;Significance: AF driving signals show promise for enabling MRgFUS tissue ablation close to the spine without overheating the bone or nearby nerve bundles.&#xD.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-05-22
DOI
https://doi.org/10.1088/1361-6560/ae7248
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anti-focus driving signals to mitigate bone heating during focused ultrasound ablation of uterine fibroids with phased arrays

Ryan M. Jones, Moslem Sadeghi-Goughari, Kullervo Hynynen
Physics in Medicine and Biology
Ultrasound and Hyperthermia Applications
article

Anti-focus driving signals to mitigate bone heating during focused ultrasound ablation of uterine fibroids with phased arrays

Ryan M. Jones, Moslem Sadeghi-Goughari, Kullervo Hynynen
article en

Abstract

OBJECTIVE: During magnetic resonance-guided focused ultrasound (MRgFUS) treatment of uterine fibroids, ablating tissue near the spine is challenging as unwanted far-field bone heating can cause pain and potentially injure nearby nerves. This study investigates an anti-focus (AF) scheme for minimizing bone heating when targeting fibroid tissue in proximity to the spine.&#xD;Approach: Acoustic and thermal simulations were conducted using 3D MRI-derived anatomical models from ten patients who underwent MRgFUS for uterine fibroids using a low-frequency (0.5 MHz) 6144-element flat fully-populated modular phased array during a clinical trial (NCT03323905). AF points were distributed over patient spine surfaces with varying densities, transducer array element-wise phase and amplitude controls were obtained via Tikhonov regularization, and the resulting temperature fields were compared to those obtained via both conventional focusing (CF) and a transducer module partial blocking (PB) approach developed to mitigate far-field bone heating [Goudarzi et al., Med. Phys. 51(12):8670-87 (2024)]. Optimal regularization parameter values were chosen to maximize the focal-to-bone heating ratio (ΔTratio) while maintaining focal integrity.&#xD;Results: For high point densities (0.25 AF/mm²), AF driving signals provided significant improvements in ΔTratio compared to CF (fold improvement: 13 ± 16, p = 0.0009) and the optimal PB approach (fold improvement: 11 ± 11, p = 0.0009), at the cost of more diffuse focusing (focal heating volumes increased 77% ± 23% vs. CF; 50% ± 33% vs. PB; p < 0.0001) and thus requiring higher acoustic power levels to maintain focal heating (increased 73% ± 19% vs. CF; 15 ± 20% vs. PB; p < 0.0001). Soft-tissue aberration corrections improved focal targeting accuracy and reduced acoustic power demands, complementing the AF strategy.&#xD;Significance: AF driving signals show promise for enabling MRgFUS tissue ablation close to the spine without overheating the bone or nearby nerve bundles.&#xD.

Physics in Medicine and Biology
University of Toronto (CA), Sunnybrook Hospital (CA), Sunnybrook Research Institute
Strategic Innovation Fund
Openalex Percentile: Top 9%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.