AI-Empowered and a Bio-/Nanoenzyme-Hybrid Multisensors Array toward Precision Diagnosis of Kidney Diseases

Chronic kidney disease (CKD) risk assessment is shifting from centralized instrument-heavy testing to personalized point-of-care evaluation enabled by portable platforms. However, integration of multibiomarker analysis and the deep learning algorithm to improve detection accuracy in CKD is still a persistent goal. Herein, this work has developed an artificial intelligence (AI)-empowered and bio-/nanoenzyme-hybrid multisensors array (AI-BMA) for multidimensional precise diagnosis of early stage CKD. The laser-induced electrochemical sensors array is functionalized by creatinine deaminase (CDI), urate oxidase (UOx), and polyaniline for the differential detection of urinary creatinine (Cr), uric acid (UA), and pH. The integrated analysis of multimodal/multimarker electrochemical characteristic spectra and one-dimensional convolutional neural network (1D-CNN) along with multilayer perceptron (MLP) establishes an end-to-end workflow from electrochemical signal acquisition to individualized CKD risk assessment. The proposed bio-/nanoenzyme-hybrid multiplexed sensors strategy demonstrates well-defined analytical performance, covering detection ranges of 3-15 mM creatinine with limit of detection of 300.50 μM, 0.1-1.0 mM uric acid with LOD value of 19.17 μM, and 3.0-9.0 pH. By employing the self-developed 1D-CNN and MLP model for multimarker joint prediction, the average prediction accuracy of CKD biomarkers reaches 98.67%. This overcomes limitations of high-dimensional electrochemical signal feature extraction and multi-index joint prediction. The robust AI-BMA platform can automatically convert complex electrochemical detection data of urinary metabolites into understandable risk stratification results. This provides an alternative solution for the early screening of kidney injury, which is expected to assist patients/clinicians in identifying CKD's risk assessment in the home-care scenario and limited resources.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-05-22
DOI
https://doi.org/10.1021/acs.analchem.6c00066
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-Empowered and a Bio-/Nanoenzyme-Hybrid Multisensors Array toward Precision Diagnosis of Kidney Diseases

Yuting Xiao, Liu S, Quanguo He, Qin Zhu et al.
Analytical Chemistry
Electrochemical sensors and biosensors
article

AI-Empowered and a Bio-/Nanoenzyme-Hybrid Multisensors Array toward Precision Diagnosis of Kidney Diseases

Yuting Xiao, Liu S, Quanguo He, Qin Zhu, Jian Yang, Shouchuan Peng, Yuyu Tan
article en

Abstract

Chronic kidney disease (CKD) risk assessment is shifting from centralized instrument-heavy testing to personalized point-of-care evaluation enabled by portable platforms. However, integration of multibiomarker analysis and the deep learning algorithm to improve detection accuracy in CKD is still a persistent goal. Herein, this work has developed an artificial intelligence (AI)-empowered and bio-/nanoenzyme-hybrid multisensors array (AI-BMA) for multidimensional precise diagnosis of early stage CKD. The laser-induced electrochemical sensors array is functionalized by creatinine deaminase (CDI), urate oxidase (UOx), and polyaniline for the differential detection of urinary creatinine (Cr), uric acid (UA), and pH. The integrated analysis of multimodal/multimarker electrochemical characteristic spectra and one-dimensional convolutional neural network (1D-CNN) along with multilayer perceptron (MLP) establishes an end-to-end workflow from electrochemical signal acquisition to individualized CKD risk assessment. The proposed bio-/nanoenzyme-hybrid multiplexed sensors strategy demonstrates well-defined analytical performance, covering detection ranges of 3-15 mM creatinine with limit of detection of 300.50 μM, 0.1-1.0 mM uric acid with LOD value of 19.17 μM, and 3.0-9.0 pH. By employing the self-developed 1D-CNN and MLP model for multimarker joint prediction, the average prediction accuracy of CKD biomarkers reaches 98.67%. This overcomes limitations of high-dimensional electrochemical signal feature extraction and multi-index joint prediction. The robust AI-BMA platform can automatically convert complex electrochemical detection data of urinary metabolites into understandable risk stratification results. This provides an alternative solution for the early screening of kidney injury, which is expected to assist patients/clinicians in identifying CKD's risk assessment in the home-care scenario and limited resources.

Analytical Chemistry
Hengyang Academy of Agricultural Sciences (CN), Hunan University of Technology (CN), University of South China (CN)
National Natural Science Foundation of China, Natural Science Foundation of Hunan Province
Good health and well-being
Openalex Percentile: Top 8%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.