Optic Nerve Sheath Diameter and Transcranial Doppler Pulsatility Index for Non-Invasive ICP Assessment in Acute Intracerebral Hemorrhage

Background: Intracranial hypertension is a critical complication of acute intracerebral hemorrhage (ICH), contributing to high early mortality and poor functional outcomes. Invasive intracranial pressure (ICP) monitoring remains the gold standard but carries procedural risks and is resource-intensive. This study evaluated the diagnostic and prognostic utility of optic nerve sheath diameter (ONSD) ultrasonography and transcranial Doppler (TCD)-derived pulsatility index (PI) as non-invasive ICP surrogates in patients with severe ICH. Methods: A prospective observational study was conducted in 42 patients with acute ICH who underwent concurrent invasive ICP monitoring and serial ONSD/PI measurements at 10 time points (T0–T9) between October 2021 and August 2024. Diagnostic performance was assessed using measurement-level receiver operating characteristic (ROC) curve analysis. Exploratory early mortality prediction was evaluated using random forest machine learning models incorporating ONSD, PI, age, and sex. Results: A total of 274 paired ONSD–PI–ICP measurements were obtained. Both ONSD and PI showed moderate positive correlations with invasive ICP (rho = 0.49 and 0.43, respectively; p < 0.001). ONSD demonstrated superior diagnostic accuracy for detecting ICP ≥ 20 mmHg (AUC = 0.83; optimal threshold: 5.88 mm; sensitivity: 81%; specificity: 82%) compared to PI (AUC = 0.75). In exploratory random forest analyses, the combined ONSD–PI model showed high apparent discrimination for elevated ICP detection (AUC = 0.98), while the model incorporating ONSD, PI, age, and sex showed promising but potentially optimistic discrimination for early mortality prediction (AUC = 0.95). These machine learning results should be interpreted cautiously because of the small sample size, repeated-measurement structure, measurement-level data partitioning, and limited number of early deaths. Conclusions: ONSD ultrasonography and TCD-derived PI showed promising performance as non-invasive ICP markers in severe acute ICH. However, because of the small sample size, repeated-measurement design, measurement-level analyses, and exploratory nature of the machine learning models, these findings require validation in larger external cohorts before routine clinical implementation.

Authors

Institutions

Publication Details

Journal
Brain Sciences
Published
2026-05-22
DOI
https://doi.org/10.3390/brainsci16060553
Primary Topic
Intracerebral and Subarachnoid Hemorrhage Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optic Nerve Sheath Diameter and Transcranial Doppler Pulsatility Index for Non-Invasive ICP Assessment in Acute Intracerebral Hemorrhage

Nghiem Xuan Hoan, Nguyen Hoang Ngoc, Nguyen Thị Cuc, Nguyen Van Van Tuyen
Brain Sciences
Intracerebral and Subarachnoid Hemorrhage Research
article

Optic Nerve Sheath Diameter and Transcranial Doppler Pulsatility Index for Non-Invasive ICP Assessment in Acute Intracerebral Hemorrhage

Nghiem Xuan Hoan, Nguyen Hoang Ngoc, Nguyen Thị Cuc, Nguyen Van Van Tuyen
article en

Abstract

Background: Intracranial hypertension is a critical complication of acute intracerebral hemorrhage (ICH), contributing to high early mortality and poor functional outcomes. Invasive intracranial pressure (ICP) monitoring remains the gold standard but carries procedural risks and is resource-intensive. This study evaluated the diagnostic and prognostic utility of optic nerve sheath diameter (ONSD) ultrasonography and transcranial Doppler (TCD)-derived pulsatility index (PI) as non-invasive ICP surrogates in patients with severe ICH. Methods: A prospective observational study was conducted in 42 patients with acute ICH who underwent concurrent invasive ICP monitoring and serial ONSD/PI measurements at 10 time points (T0–T9) between October 2021 and August 2024. Diagnostic performance was assessed using measurement-level receiver operating characteristic (ROC) curve analysis. Exploratory early mortality prediction was evaluated using random forest machine learning models incorporating ONSD, PI, age, and sex. Results: A total of 274 paired ONSD–PI–ICP measurements were obtained. Both ONSD and PI showed moderate positive correlations with invasive ICP (rho = 0.49 and 0.43, respectively; p < 0.001). ONSD demonstrated superior diagnostic accuracy for detecting ICP ≥ 20 mmHg (AUC = 0.83; optimal threshold: 5.88 mm; sensitivity: 81%; specificity: 82%) compared to PI (AUC = 0.75). In exploratory random forest analyses, the combined ONSD–PI model showed high apparent discrimination for elevated ICP detection (AUC = 0.98), while the model incorporating ONSD, PI, age, and sex showed promising but potentially optimistic discrimination for early mortality prediction (AUC = 0.95). These machine learning results should be interpreted cautiously because of the small sample size, repeated-measurement structure, measurement-level data partitioning, and limited number of early deaths. Conclusions: ONSD ultrasonography and TCD-derived PI showed promising performance as non-invasive ICP markers in severe acute ICH. However, because of the small sample size, repeated-measurement design, measurement-level analyses, and exploratory nature of the machine learning models, these findings require validation in larger external cohorts before routine clinical implementation.

Brain SciencesVol. 16(6)
Vietnam National University, Hanoi (VN), Vietnamese - German Center of Excellence in Medical Research (VN), 108 Military Central Hospital (VN)
Openalex Percentile: Top 5%
Intracerebral and Subarachnoid Hemorrhage Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.