Patient-Specific Blood Pressure Estimation Using Elastography-Integrated Arterial Tonometry: Design, Development, and Experimental Evaluation in a Phantom Model

Abstract Accurate assessment of arterial blood pressure (BP) and vascular stiffness is critical for diagnosing and monitoring car-diovascular disease. Arterial tonometry enables direct pulse wave acquisition and has been widely explored for noninvasive, wearable BP estimation. However, tonometry-based approaches typically rely on generalized arterial biomechanical parameters that exhibit substantial intersubject variability and can limit accuracy, particularly in pathological conditions. To address this limitation, we present a hybrid sensing framework that integrates shear wave elastography (SWE) with arterial tonometry to enable patient-specific biomechanical parameterization. The pro-posed device simultaneously acquires arterial stiffness metrics and pulse pressure waveforms, which are incorporated into a validated physics-driven model for continuous BP estimation. By combining elastography-derived mechanical priors with direct pulse wave measurements, this approach improves personalization and physiological fidelity of noninvasive BP monitoring. The proposed hybrid system demonstrates the potential for more accurate, patient-specific, and continuous blood pressure assessment, with implications for wearable cardiovascular monitoring and precision diagnostics.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2026-05-22
DOI
https://doi.org/10.1115/1.4071991
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient-Specific Blood Pressure Estimation Using Elastography-Integrated Arterial Tonometry: Design, Development, and Experimental Evaluation in a Phantom Model

Q uan Zhang, Ge Zhu, Nora Watson, David Minnie et al.
Journal of Medical Devices
Cardiovascular Health and Disease Prevention
article

Patient-Specific Blood Pressure Estimation Using Elastography-Integrated Arterial Tonometry: Design, Development, and Experimental Evaluation in a Phantom Model

Q uan Zhang, Ge Zhu, Nora Watson, David Minnie, Yihao Zheng
article en

Abstract

Abstract Accurate assessment of arterial blood pressure (BP) and vascular stiffness is critical for diagnosing and monitoring car-diovascular disease. Arterial tonometry enables direct pulse wave acquisition and has been widely explored for noninvasive, wearable BP estimation. However, tonometry-based approaches typically rely on generalized arterial biomechanical parameters that exhibit substantial intersubject variability and can limit accuracy, particularly in pathological conditions. To address this limitation, we present a hybrid sensing framework that integrates shear wave elastography (SWE) with arterial tonometry to enable patient-specific biomechanical parameterization. The pro-posed device simultaneously acquires arterial stiffness metrics and pulse pressure waveforms, which are incorporated into a validated physics-driven model for continuous BP estimation. By combining elastography-derived mechanical priors with direct pulse wave measurements, this approach improves personalization and physiological fidelity of noninvasive BP monitoring. The proposed hybrid system demonstrates the potential for more accurate, patient-specific, and continuous blood pressure assessment, with implications for wearable cardiovascular monitoring and precision diagnostics.

Journal of Medical Devices
Worcester Polytechnic Institute (US), Massachusetts General Hospital (US)
Good health and well-being
Openalex Percentile: Top 6%
Cardiovascular Health and Disease Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.