Next generation spray‐dried on‐demand plasma: A multicenter, randomized, dose‐escalation, first‐in‐human safety study

BACKGROUND: Prehospital plasma transfusion for patients at risk of hemorrhagic shock reduces mortality, but cold-chain and logistical constraints limit product availability. This study reports the first-in-human clinical evaluation of a new spray-dried plasma product, Frontline On-Demand Plasma (ODP). METHODS: Twenty-four healthy volunteers were sequentially enrolled into three dose-escalation cohorts. Autologous apheresis plasma was processed into plasma frozen within 24 h (PF24), with half of each collection manufactured into ODP. Cohort 1 (n = 6) received 200 mL ODP; Cohort 2 (n = 6) received 400 mL; and Cohort 3 (n = 12) was a randomized, double-blind crossover comparing 800 mL ODP with 800 mL PF24. Subjects were monitored for 28 days after each infusion. The primary endpoint was treatment-emergent adverse events (TEAEs). RESULTS: System verification data demonstrated preservation of protein content in spray-dried plasma. All 24 participants completed the study and infusions were well tolerated. Thirty-five TEAEs occurred in 18 subjects; 34 were unrelated or unlikely related to infusion. In Cohort 3, TEAEs occurred at similar frequencies after ODP and PF24. Headache was the most common TEAE. Minor coagulation parameter changes were observed but were not clinically significant. Out-of-range coagulation values were evenly distributed between treatment groups. CONCLUSIONS: Spray-dried plasma demonstrated a safety profile comparable to standard frozen plasma, with no thromboembolic events observed. Its durable plastic packaging and rapid reconstitution support its potential for widespread use in out-of-hospital care, including emergency and austere environments.

Authors

Institutions

Publication Details

Journal
Transfusion
Published
2026-05-21
DOI
https://doi.org/10.1111/trf.70262
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Next generation spray‐dried on‐demand plasma: A multicenter, randomized, dose‐escalation, first‐in‐human safety study

Stephanie Post, Mamie Thant, Neeta Rugg, Jihae Sohn et al.
Transfusion
Blood transfusion and management
article

Next generation spray‐dried on‐demand plasma: A multicenter, randomized, dose‐escalation, first‐in‐human safety study

Stephanie Post, Mamie Thant, Neeta Rugg, Jihae Sohn, Susan F. Leitman, Mark A. Popovsky, Lindsay Gingras, Lisa Buckley, Andrew P. Cap, Jose A. Cancelas, Angela Treml, Caroline Alquist, Dawn Munoz, Shawnagay Nestheide
article en

Abstract

BACKGROUND: Prehospital plasma transfusion for patients at risk of hemorrhagic shock reduces mortality, but cold-chain and logistical constraints limit product availability. This study reports the first-in-human clinical evaluation of a new spray-dried plasma product, Frontline On-Demand Plasma (ODP). METHODS: Twenty-four healthy volunteers were sequentially enrolled into three dose-escalation cohorts. Autologous apheresis plasma was processed into plasma frozen within 24 h (PF24), with half of each collection manufactured into ODP. Cohort 1 (n = 6) received 200 mL ODP; Cohort 2 (n = 6) received 400 mL; and Cohort 3 (n = 12) was a randomized, double-blind crossover comparing 800 mL ODP with 800 mL PF24. Subjects were monitored for 28 days after each infusion. The primary endpoint was treatment-emergent adverse events (TEAEs). RESULTS: System verification data demonstrated preservation of protein content in spray-dried plasma. All 24 participants completed the study and infusions were well tolerated. Thirty-five TEAEs occurred in 18 subjects; 34 were unrelated or unlikely related to infusion. In Cohort 3, TEAEs occurred at similar frequencies after ODP and PF24. Headache was the most common TEAE. Minor coagulation parameter changes were observed but were not clinically significant. Out-of-range coagulation values were evenly distributed between treatment groups. CONCLUSIONS: Spray-dried plasma demonstrated a safety profile comparable to standard frozen plasma, with no thromboembolic events observed. Its durable plastic packaging and rapid reconstitution support its potential for widespread use in out-of-hospital care, including emergency and austere environments.

Transfusion
Harvard University (US), Spaulding Clinical Research (United States) (US), Versiti Blood Center of Wisconsin (US), Dana-Farber Cancer Institute (US), Beverly Hospital (US), University of Cincinnati (US), University of Cincinnati Medical Center (US)
Good health and well-being
Openalex Percentile: Top 7%
Blood transfusion and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.