Impact of hybrid solar and wind distributed generators on transient stability of captive power systems

This paper investigates the impact of solar and wind distributed generators on the transient stability of a 39-bus industrial power system. The system is analyzed under different configurations, including wind-only, solar-only, and hybrid DG integration. Critical Clearing Time (CCT), active power, and reactive power are used as performance metrics. The results show that DG integration improves system stability compared to the baseline case. Specifically, the CCT increases from 0.018 s (without DG) to 0.0248 s with wind DG, and up to 0.3168 s with solar DG. The hybrid configuration results in a CCT of 0.0297 s. These results indicate that solar DG provides the highest improvement in transient stability due to better voltage support characteristics. The study highlights the importance of DG type and placement in improving stability and provides insights for industrial power system design.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-22
DOI
https://doi.org/10.1038/s41598-026-51606-8
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of hybrid solar and wind distributed generators on transient stability of captive power systems

K. G. Ravindra, P. S D Bhimaraju, K V S Ramachandra Murthy
Scientific Reports
Power System Optimization and Stability
article

Impact of hybrid solar and wind distributed generators on transient stability of captive power systems

K. G. Ravindra, P. S D Bhimaraju, K V S Ramachandra Murthy
article en

Abstract

This paper investigates the impact of solar and wind distributed generators on the transient stability of a 39-bus industrial power system. The system is analyzed under different configurations, including wind-only, solar-only, and hybrid DG integration. Critical Clearing Time (CCT), active power, and reactive power are used as performance metrics. The results show that DG integration improves system stability compared to the baseline case. Specifically, the CCT increases from 0.018 s (without DG) to 0.0248 s with wind DG, and up to 0.3168 s with solar DG. The hybrid configuration results in a CCT of 0.0297 s. These results indicate that solar DG provides the highest improvement in transient stability due to better voltage support characteristics. The study highlights the importance of DG type and placement in improving stability and provides insights for industrial power system design.

Scientific Reports
Jawaharlal Nehru Technological University, Kakinada (IN), Aditya Birla (India) (IN)
Affordable and clean energy
Openalex Percentile: Top 9%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of hybrid solar and wind distributed generators on transient stability of captive power systems — K. G. Ravindra, P. S D Bhimaraju, et al. · Scientific Reports (2026) | TGRS Research Map | TGRS