Use of Lighted Urologic Guide Wires in Sialendoscopy: A Proof‐of‐Concept Study

In combined approach sialendoscopy surgery, the sialendoscope tip may be used to illuminate the duct and serve as a visual target during cut down dissection. While this can assist in identifying the location of the duct and any obstruction, it also runs the risk of damaging the endoscope. In this prospective single-arm trial, we investigated the safety of an infrared ureteral stent as a means of identifying the path of the salivary ducts. Five patients were enrolled to test the feasibility and safety of this device while undergoing sialendoscopy, which was trialed in 2 submandibular glands and 4 parotid glands. There was 1 instance of device failure which required intraductal exploration to rectify. Infrared light was able to be identified through tissue both transorally and transcutaneously, and in some instances was capable of identifying duct location when visible light was not. Future development in this technology targeting sialendoscopy may provide significant clinical utility for otolaryngologists.

Authors

Institutions

Publication Details

Journal
Otolaryngology
Published
2026-05-22
DOI
https://doi.org/10.1002/ohn.70259
Primary Topic
Salivary Gland Tumors Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of Lighted Urologic Guide Wires in Sialendoscopy: A Proof‐of‐Concept Study

Monika E. Freiser, John Dewey
Otolaryngology
Salivary Gland Tumors Diagnosis and Treatment
article

Use of Lighted Urologic Guide Wires in Sialendoscopy: A Proof‐of‐Concept Study

Monika E. Freiser, John Dewey
article en

Abstract

In combined approach sialendoscopy surgery, the sialendoscope tip may be used to illuminate the duct and serve as a visual target during cut down dissection. While this can assist in identifying the location of the duct and any obstruction, it also runs the risk of damaging the endoscope. In this prospective single-arm trial, we investigated the safety of an infrared ureteral stent as a means of identifying the path of the salivary ducts. Five patients were enrolled to test the feasibility and safety of this device while undergoing sialendoscopy, which was trialed in 2 submandibular glands and 4 parotid glands. There was 1 instance of device failure which required intraductal exploration to rectify. Infrared light was able to be identified through tissue both transorally and transcutaneously, and in some instances was capable of identifying duct location when visible light was not. Future development in this technology targeting sialendoscopy may provide significant clinical utility for otolaryngologists.

Otolaryngology
West Virginia University (US)
Good health and well-being
Openalex Percentile: Top 5%
Salivary Gland Tumors Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.