Background Tendon structure evaluation is fundamental for research and clinical practice, with the ultrasonography being the primary macrostructural imaging tool. Nevertheless, microstructural tendon adaptations require highly invasive procedures to be evaluated, i.e. , tendon biopsies. To address this, the present study aims to explore the reliability and sensitivity to change of a minimally invasive Intra-Tendon Bioimpedance Spectroscopy (IT-BIS), which measures the tendon’s electrical response across frequencies using fine needles inserted longitudinally along the tendon. Methods Forty healthy volunteers were placed in the supine position with the knee flexed at 30°. Four needles were inserted under ultrasound guidance along the patellar tendon and connected to the IT-BIS device in a tetrapolar configuration for impedance measurement. IT-BIS was assessed twice per session and there were two sessions separated by at least two weeks. To evaluate intra- and inter-session reliability we calculated indexes of relative (Intra-class Correlation Coefficient: ICC 1,1 ) and absolute reliability (Standard Error of Measurement: SEM. Minimal Detectable Change: MDC). Resistance, reactance, magnitude, and phase angle were measured across frequencies to characterize the tendon architecture. The high and low frecuency cutoff was established by the experimental characteristic frequency of our data at basal conditions. Also, intra-tendon electrolysis was applied in the second session to determine sensitivity to change of the IT-BIS. Results IT-BIS showed excellent intrasession reliability across all parameters in both high and low frequency ranges with ICCs of 0.927 to 0.999. However, inter-session reliability was predominant poor (ICCs 0.087 to 0.390), with moderate reliability in phase angle at low frequency (ICC = 0.528). Sensitivity to change by needle insertion was evidenced at low frequency in all parameters, specifically resistance ( p = 0.009; SRM = −0.54), reactance ( p = 0.004; SRM −0.61), magnitude ( p = 0.039; SRM = −0.4), and phase angle ( p = 0.02; SRM = −0.67). However, sensitivy to change by percutaneous electrolysis was at high frequency, being resistance ( p = 0.002; SRM = 0.68), reactance ( p = 0.037; SRM = 0.39), magnitude ( p = 0.01; SRM = 0.55), and phase angle ( p = 0.006; SRM = 0.57). Minimal adverse effects were reported: 4.63% pain occurrence rate and were consistently mild and transient. Conclusion Minimally invasive IT-BIS showed excellent intra-session reliability but poor-to-moderate inter-session reliability, underscoring the need for further methodological standardization. The technique demonstrated sensitivity to acute physiological changes, identifying needle insertion effects at low frequencies and percutaneous electrolysis effects at high frequencies. Adverse effects were minimal and mild. Overall, IT-BIS emerges as a safe and promising tool for tendon assessment.

Authors

Institutions

Publication Details

Journal
PeerJ
Published
2026-05-21
DOI
https://doi.org/10.7717/peerj.21084
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intratendon bioimpedance spectroscopy: a first step exploring reliability and sensitivity to change

Adrián Escriche-Escuder, Miguel Delicado Miralles, Rodrigo Martín‐San Agustín, Patricia Beltrá et al.
PeerJ
Body Composition Measurement Techniques
article

Intratendon bioimpedance spectroscopy: a first step exploring reliability and sensitivity to change

Adrián Escriche-Escuder, Miguel Delicado Miralles, Rodrigo Martín‐San Agustín, Patricia Beltrá, Emilio Tomás-Muñoz, Enrique Velasco
article en

Abstract

Background Tendon structure evaluation is fundamental for research and clinical practice, with the ultrasonography being the primary macrostructural imaging tool. Nevertheless, microstructural tendon adaptations require highly invasive procedures to be evaluated, i.e. , tendon biopsies. To address this, the present study aims to explore the reliability and sensitivity to change of a minimally invasive Intra-Tendon Bioimpedance Spectroscopy (IT-BIS), which measures the tendon’s electrical response across frequencies using fine needles inserted longitudinally along the tendon. Methods Forty healthy volunteers were placed in the supine position with the knee flexed at 30°. Four needles were inserted under ultrasound guidance along the patellar tendon and connected to the IT-BIS device in a tetrapolar configuration for impedance measurement. IT-BIS was assessed twice per session and there were two sessions separated by at least two weeks. To evaluate intra- and inter-session reliability we calculated indexes of relative (Intra-class Correlation Coefficient: ICC 1,1 ) and absolute reliability (Standard Error of Measurement: SEM. Minimal Detectable Change: MDC). Resistance, reactance, magnitude, and phase angle were measured across frequencies to characterize the tendon architecture. The high and low frecuency cutoff was established by the experimental characteristic frequency of our data at basal conditions. Also, intra-tendon electrolysis was applied in the second session to determine sensitivity to change of the IT-BIS. Results IT-BIS showed excellent intrasession reliability across all parameters in both high and low frequency ranges with ICCs of 0.927 to 0.999. However, inter-session reliability was predominant poor (ICCs 0.087 to 0.390), with moderate reliability in phase angle at low frequency (ICC = 0.528). Sensitivity to change by needle insertion was evidenced at low frequency in all parameters, specifically resistance ( p = 0.009; SRM = −0.54), reactance ( p = 0.004; SRM −0.61), magnitude ( p = 0.039; SRM = −0.4), and phase angle ( p = 0.02; SRM = −0.67). However, sensitivy to change by percutaneous electrolysis was at high frequency, being resistance ( p = 0.002; SRM = 0.68), reactance ( p = 0.037; SRM = 0.39), magnitude ( p = 0.01; SRM = 0.55), and phase angle ( p = 0.006; SRM = 0.57). Minimal adverse effects were reported: 4.63% pain occurrence rate and were consistently mild and transient. Conclusion Minimally invasive IT-BIS showed excellent intra-session reliability but poor-to-moderate inter-session reliability, underscoring the need for further methodological standardization. The technique demonstrated sensitivity to acute physiological changes, identifying needle insertion effects at low frequencies and percutaneous electrolysis effects at high frequencies. Adverse effects were minimal and mild. Overall, IT-BIS emerges as a safe and promising tool for tendon assessment.

PeerJVol. 14
Universitat de Miguel Hernández d'Elx (ES), Universitat de València (ES), Alu Group (Spain) (ES), KU Leuven (BE)
No poverty
Openalex Percentile: Top 6%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.