High-frequency low-tidal-volume ventilation reduces loop catheter displacement during pulsed field ablation for pulmonary vein isolation

Respiratory motion during pulmonary vein isolation (PVI) using pulsed field ablation (PFA) can compromise catheter stability and procedural precision. Although high-frequency, low-tidal-volume ventilation (HFLTV) has been proposed to reduce diaphragmatic excursion, quantitative data evaluating its effect on catheter tip displacement during PFA are limited. This retrospective observational study included 28 consecutive patients with atrial fibrillation (paroxysmal, n = 21; persistent, n = 7) who underwent PVI using PFA under general anesthesia. Catheter stability was quantitatively assessed by measuring the vertical displacement of the distal catheter tip during a single respiratory cycle at the right and left inferior pulmonary veins under intermittent positive pressure ventilation and HFLTV within the same patients. HFLTV significantly reduced catheter tip displacement at both pulmonary veins compared with intermittent positive pressure ventilation. Median displacement at the right inferior pulmonary vein decreased from 2.7 to 1.4 mm (median paired difference, 1.15 mm; 95% CI 0.25-2.25; p = 0.003), and at the left inferior pulmonary vein from 4.8 to 1.3 mm (median paired difference, 2.95 mm; 95% CI 1.50-3.80; p < 0.001). End-tidal carbon dioxide levels increased modestly during HFLTV without clinically significant hemodynamic instability. HFLTV significantly reduced catheter tip displacement during PVI using PFA. These findings suggest that HFLTV may be a useful ventilatory strategy for improving catheter stability during PFA procedures under general anesthesia.

Authors

Institutions

Publication Details

Journal
Journal of Anesthesia
Published
2026-05-21
DOI
https://doi.org/10.1007/s00540-026-03785-x
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-frequency low-tidal-volume ventilation reduces loop catheter displacement during pulsed field ablation for pulmonary vein isolation

Ryosuke Osawa, Tomoyuki Saito, Hideyuki Aoki, Shiro Nakahara
Journal of Anesthesia
Atrial Fibrillation Management and Outcomes
article

High-frequency low-tidal-volume ventilation reduces loop catheter displacement during pulsed field ablation for pulmonary vein isolation

Ryosuke Osawa, Tomoyuki Saito, Hideyuki Aoki, Shiro Nakahara
article en

Abstract

Respiratory motion during pulmonary vein isolation (PVI) using pulsed field ablation (PFA) can compromise catheter stability and procedural precision. Although high-frequency, low-tidal-volume ventilation (HFLTV) has been proposed to reduce diaphragmatic excursion, quantitative data evaluating its effect on catheter tip displacement during PFA are limited. This retrospective observational study included 28 consecutive patients with atrial fibrillation (paroxysmal, n = 21; persistent, n = 7) who underwent PVI using PFA under general anesthesia. Catheter stability was quantitatively assessed by measuring the vertical displacement of the distal catheter tip during a single respiratory cycle at the right and left inferior pulmonary veins under intermittent positive pressure ventilation and HFLTV within the same patients. HFLTV significantly reduced catheter tip displacement at both pulmonary veins compared with intermittent positive pressure ventilation. Median displacement at the right inferior pulmonary vein decreased from 2.7 to 1.4 mm (median paired difference, 1.15 mm; 95% CI 0.25-2.25; p = 0.003), and at the left inferior pulmonary vein from 4.8 to 1.3 mm (median paired difference, 2.95 mm; 95% CI 1.50-3.80; p < 0.001). End-tidal carbon dioxide levels increased modestly during HFLTV without clinically significant hemodynamic instability. HFLTV significantly reduced catheter tip displacement during PVI using PFA. These findings suggest that HFLTV may be a useful ventilatory strategy for improving catheter stability during PFA procedures under general anesthesia.

Journal of Anesthesia
Dokkyo Medical University Saitama Medical Center (JP), Social Insurance Saitama Chuo Hospital (JP), Dokkyo Medical University (JP)
Dokkyo Medical University
Openalex Percentile: Top 6%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.