Resilience-Driven Overload Protection Framework for Mitigating Cascading Failures in Power Systems
Multiple-fault events can initiate overload propagation and cascading outages, resulting in severe load loss and reduced system resilience. Therefore, beyond conventional protection concepts based on the (n − 1) criterion, there is also a need to address multiple-fault events to minimize loss of load. This paper presents an optimized overload tripping scheme to mitigate cascading outages in high-voltage grids under multiple-fault conditions, where selected line switches or circuit breakers are opened in a controlled manner to isolate limited grid sections, minimize interrupted load, and prevent further overload propagation. The method combines inverse definite minimum time relay modeling with a heuristic graph-search algorithm implemented in pandapower to identify feasible switching actions that minimize load loss while preventing overload propagation. The approach is demonstrated on SimBench high-voltage urban and mixed benchmark grids under double-line fault scenarios. In the urban grid, the proposed scheme reduces the maximum load loss from 34.0% to 2.4%, while in the mixed grid, the reduction is from 50.3% to 5.2%. A SAIFI-inspired resilience proxy is introduced to quantify the reduction in customer/load interruptions, showing a resilience improvement factor of about 3.6 for cascading scenarios. In addition, thermal inertia analysis indicates that corrective switching must be completed within approximately 5 min to remain within line-temperature limits. The analysis is based on quasi-steady-state power-flow and relay simulations; transient stability effects are outside the scope of this study. The results demonstrate that the optimized overload tripping scheme is a promising adaptive protection strategy for improving grid resilience under severe contingency conditions.
Authors
- Christian Hachmann (ORCID: https://orcid.org/0000-0002-7227-3986)
- Gourab Schmidt-Banerjee (ORCID: https://orcid.org/0000-0003-4537-6979)
- Martin Braun (ORCID: https://orcid.org/0000-0003-0857-6760)
Institutions
- University of Kassel (DE)
- Fraunhofer Institute for Energy Economics and Energy System Technology (DE)
Publication Details
- Journal
- Energies
- Published
- 2026-05-21
- DOI
- https://doi.org/10.3390/en19102468
- Primary Topic
- Optimal Power Flow Distribution
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Bundesministerium für Bildung und Forschung
- Universität Kassel