Resilience-Driven Overload Protection Framework for Mitigating Cascading Failures in Power Systems

Multiple-fault events can initiate overload propagation and cascading outages, resulting in severe load loss and reduced system resilience. Therefore, beyond conventional protection concepts based on the (n − 1) criterion, there is also a need to address multiple-fault events to minimize loss of load. This paper presents an optimized overload tripping scheme to mitigate cascading outages in high-voltage grids under multiple-fault conditions, where selected line switches or circuit breakers are opened in a controlled manner to isolate limited grid sections, minimize interrupted load, and prevent further overload propagation. The method combines inverse definite minimum time relay modeling with a heuristic graph-search algorithm implemented in pandapower to identify feasible switching actions that minimize load loss while preventing overload propagation. The approach is demonstrated on SimBench high-voltage urban and mixed benchmark grids under double-line fault scenarios. In the urban grid, the proposed scheme reduces the maximum load loss from 34.0% to 2.4%, while in the mixed grid, the reduction is from 50.3% to 5.2%. A SAIFI-inspired resilience proxy is introduced to quantify the reduction in customer/load interruptions, showing a resilience improvement factor of about 3.6 for cascading scenarios. In addition, thermal inertia analysis indicates that corrective switching must be completed within approximately 5 min to remain within line-temperature limits. The analysis is based on quasi-steady-state power-flow and relay simulations; transient stability effects are outside the scope of this study. The results demonstrate that the optimized overload tripping scheme is a promising adaptive protection strategy for improving grid resilience under severe contingency conditions.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-05-21
DOI
https://doi.org/10.3390/en19102468
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resilience-Driven Overload Protection Framework for Mitigating Cascading Failures in Power Systems

Christian Hachmann, Gourab Schmidt-Banerjee, Martin Braun
Energies
Optimal Power Flow Distribution
article

Resilience-Driven Overload Protection Framework for Mitigating Cascading Failures in Power Systems

Christian Hachmann, Gourab Schmidt-Banerjee, Martin Braun
article en

Abstract

Multiple-fault events can initiate overload propagation and cascading outages, resulting in severe load loss and reduced system resilience. Therefore, beyond conventional protection concepts based on the (n − 1) criterion, there is also a need to address multiple-fault events to minimize loss of load. This paper presents an optimized overload tripping scheme to mitigate cascading outages in high-voltage grids under multiple-fault conditions, where selected line switches or circuit breakers are opened in a controlled manner to isolate limited grid sections, minimize interrupted load, and prevent further overload propagation. The method combines inverse definite minimum time relay modeling with a heuristic graph-search algorithm implemented in pandapower to identify feasible switching actions that minimize load loss while preventing overload propagation. The approach is demonstrated on SimBench high-voltage urban and mixed benchmark grids under double-line fault scenarios. In the urban grid, the proposed scheme reduces the maximum load loss from 34.0% to 2.4%, while in the mixed grid, the reduction is from 50.3% to 5.2%. A SAIFI-inspired resilience proxy is introduced to quantify the reduction in customer/load interruptions, showing a resilience improvement factor of about 3.6 for cascading scenarios. In addition, thermal inertia analysis indicates that corrective switching must be completed within approximately 5 min to remain within line-temperature limits. The analysis is based on quasi-steady-state power-flow and relay simulations; transient stability effects are outside the scope of this study. The results demonstrate that the optimized overload tripping scheme is a promising adaptive protection strategy for improving grid resilience under severe contingency conditions.

EnergiesVol. 19(10)
University of Kassel (DE), Fraunhofer Institute for Energy Economics and Energy System Technology (DE)
Bundesministerium für Bildung und Forschung, Universität Kassel
Sustainable cities and communities
Openalex Percentile: Top 9%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.