Pulmonary Function in Parkinson’s Disease: A Comparative Study of Spirometry and Impulse Oscillometry

Background/Objectives: Respiratory dysfunction in Parkinson’s disease (PD) is a clinically relevant but frequently underrecognized manifestation associated with functional impairment and increased risk of respiratory complications. This study compared spirometry and impulse oscillometry (IOS) in the assessment of respiratory function in PD, with particular focus on the detection of subtle or peripheral airway abnormalities. Methods: A prospective, single-center, cross-sectional study was conducted, including 108 participants (55 patients with PD and 53 control subjects). Pulmonary function was evaluated using standardized spirometry and IOS protocols. Group comparisons were performed using non-parametric tests, while multivariable regression analyses adjusted for potential confounding factors, including age, body mass index, smoking status, pollutant exposure, and cardiovascular comorbidities. Results: IOS identified a higher frequency of abnormal categorical findings compared with spirometry, including among subjects with normal spirometric values. Although dyspnea was more frequent in patients with PD in unadjusted analyses, multivariable regression demonstrated that PD was not an independent predictor of respiratory dysfunction. Pollutant exposure was significantly associated with abnormal IOS findings (p = 0.011). No significant differences were observed between PD and control groups regarding continuous spirometric or oscillometric parameters. Only a weak association between disease severity and FEV1 (%) was identified, whereas no significant correlations were observed for oscillometric parameters. Conclusions: IOS may provide complementary information regarding subtle or peripheral respiratory abnormalities in patients with PD. The findings suggest that respiratory alterations in this population are likely multifactorial and not independently determined by PD itself. Incorporating oscillometric assessment into respiratory evaluation may contribute to the identification of subtle respiratory mechanical alterations in patients with PD.

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2026-05-21
DOI
https://doi.org/10.3390/biomedicines14051176
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulmonary Function in Parkinson’s Disease: A Comparative Study of Spirometry and Impulse Oscillometry

V. ZAMFIR, Ariadna-Petronela Fildan, Nicoleta-Larisa Șerban, Any Axelerad et al.
Biomedicines
Chronic Obstructive Pulmonary Disease (COPD) Research
article

Pulmonary Function in Parkinson’s Disease: A Comparative Study of Spirometry and Impulse Oscillometry

V. ZAMFIR, Ariadna-Petronela Fildan, Nicoleta-Larisa Șerban, Any Axelerad, Adina-Milena Man, Irene Rășanu, Andreea-Cristina Postu, Alexandra-Cristiana Gache, Elena Danteș
article en

Abstract

Background/Objectives: Respiratory dysfunction in Parkinson’s disease (PD) is a clinically relevant but frequently underrecognized manifestation associated with functional impairment and increased risk of respiratory complications. This study compared spirometry and impulse oscillometry (IOS) in the assessment of respiratory function in PD, with particular focus on the detection of subtle or peripheral airway abnormalities. Methods: A prospective, single-center, cross-sectional study was conducted, including 108 participants (55 patients with PD and 53 control subjects). Pulmonary function was evaluated using standardized spirometry and IOS protocols. Group comparisons were performed using non-parametric tests, while multivariable regression analyses adjusted for potential confounding factors, including age, body mass index, smoking status, pollutant exposure, and cardiovascular comorbidities. Results: IOS identified a higher frequency of abnormal categorical findings compared with spirometry, including among subjects with normal spirometric values. Although dyspnea was more frequent in patients with PD in unadjusted analyses, multivariable regression demonstrated that PD was not an independent predictor of respiratory dysfunction. Pollutant exposure was significantly associated with abnormal IOS findings (p = 0.011). No significant differences were observed between PD and control groups regarding continuous spirometric or oscillometric parameters. Only a weak association between disease severity and FEV1 (%) was identified, whereas no significant correlations were observed for oscillometric parameters. Conclusions: IOS may provide complementary information regarding subtle or peripheral respiratory abnormalities in patients with PD. The findings suggest that respiratory alterations in this population are likely multifactorial and not independently determined by PD itself. Incorporating oscillometric assessment into respiratory evaluation may contribute to the identification of subtle respiratory mechanical alterations in patients with PD.

BiomedicinesVol. 14(5)
Ovidius University (RO), Iuliu Hațieganu University of Medicine and Pharmacy (RO), Clinical Emergency Hospital Bucharest (RO), Clinica de Pneumologie Iaşi (RO), Constanta Maritime University (RO), Constantza Port (Romania) (RO), Spitalul Clinic Județean de Urgență Cluj-Napoca (RO)
Good health and well-being
Openalex Percentile: Top 6%
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.