Resonance Mechanism Analysis and Suppression of Grid-Connected Energy Storage Power Station Inverter

The increasingly prominent “double-high” characteristics (high penetration of renewable energy and high proportion of power electronic devices) in modern power systems pose severe challenges to secure and stable operation, especially due to wideband oscillations induced by grid-connected inverters. In view of the fact that existing impedance modeling for grid-forming control often neglects the decoupling effect of the LC filter capacitor and the dynamics of inner voltage/current loops, leading to inaccurate characterization of mid-to-high frequency impedance, this paper aims to establish more accurate impedance models for grid-connected inverters and to develop effective oscillation mitigation methods accordingly. First, the harmonic linearization method is adopted to derive refined positive- and negative-sequence impedance analytical models for NPC inverters under both grid-following and grid-forming control. Second, simulation-based frequency scanning is conducted to validate the accuracy of the proposed models, and the differences in system resonance characteristics under the two control modes are comparatively analyzed. Finally, oscillation suppression strategies based on active damping and virtual impedance are, respectively, designed. The results show that the proposed models can accurately characterize mid-to-high frequency impedance, reveal the distinct resonance mechanisms of different control modes, and the proposed suppression strategies can effectively attenuate wideband oscillations. These findings provide theoretical foundations and practical technical pathways for stability analysis and optimization design of inverter-grid systems in high-renewable-penetration scenarios.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-05-21
DOI
https://doi.org/10.3390/electronics15102221
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resonance Mechanism Analysis and Suppression of Grid-Connected Energy Storage Power Station Inverter

JunYuan Zhang, Shihong Shi, Lianhui Ning, Xinmei Gu et al.
Electronics
Microgrid Control and Optimization
article

Resonance Mechanism Analysis and Suppression of Grid-Connected Energy Storage Power Station Inverter

JunYuan Zhang, Shihong Shi, Lianhui Ning, Xinmei Gu, Weihan Hao, Tiantian He, Min Zhou, Weiheng Kuang, Sisi Chen, Qingxin Wang, Jinchuan Guo
article en

Abstract

The increasingly prominent “double-high” characteristics (high penetration of renewable energy and high proportion of power electronic devices) in modern power systems pose severe challenges to secure and stable operation, especially due to wideband oscillations induced by grid-connected inverters. In view of the fact that existing impedance modeling for grid-forming control often neglects the decoupling effect of the LC filter capacitor and the dynamics of inner voltage/current loops, leading to inaccurate characterization of mid-to-high frequency impedance, this paper aims to establish more accurate impedance models for grid-connected inverters and to develop effective oscillation mitigation methods accordingly. First, the harmonic linearization method is adopted to derive refined positive- and negative-sequence impedance analytical models for NPC inverters under both grid-following and grid-forming control. Second, simulation-based frequency scanning is conducted to validate the accuracy of the proposed models, and the differences in system resonance characteristics under the two control modes are comparatively analyzed. Finally, oscillation suppression strategies based on active damping and virtual impedance are, respectively, designed. The results show that the proposed models can accurately characterize mid-to-high frequency impedance, reveal the distinct resonance mechanisms of different control modes, and the proposed suppression strategies can effectively attenuate wideband oscillations. These findings provide theoretical foundations and practical technical pathways for stability analysis and optimization design of inverter-grid systems in high-renewable-penetration scenarios.

ElectronicsVol. 15(10)
Guangzhou Design Institute (CN), Guangdong Hydropower Planning & Design Institute (CN), Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 6%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.