In-Use Stability and Device Compatibility Define Clinically Actionable Handling Limits for a GMP-Produced Attenuated Listeria monocytogenes Vaccine Expressing GUCY2C

Background: Live-attenuated Listeria monocytogenes (Lm) vectors are a clinically validated cancer immunotherapy platform, but translation requires reproducible, clinically realistic workflows for dose preparation and infusion. For live bacterial products, in-use stability and device compatibility can drive dose variability through adsorption, settling, and device losses. Methods: We developed and GMP-manufactured an attenuated Lm vaccine expressing human GUCY2C (Lm-GUCY2C) and performed translational characterization, including construct verification and immunogenicity readouts, and defined the administration-focused in-use stability and device compatibility. Post-thaw stability was assessed in primary cryovials and during preparation and delivery from 250 mL saline infusion bags using standard clinical devices (syringes/needles, filter-free IV tubing) and OnGuard2 closed-system components. Samples were collected over 24 h at room temperature, and viable Lm-GUCY2C were quantified by CFU recovery. Results: Lm-GUCY2C remained stable in thawed cryovials for 24 h with no significant CFU loss. High-dose infusion bags (3 × 109 CFU/bag) maintained CFU recovery through 6 h, whereas low-dose bags (3 × 108 CFU/bag) exhibited significant losses beginning at 3 h, supporting a practical in-use window of up to 2 h for low-dose preparations. OnGuard2 intravenous (i.v.) connectors did not measurably affect CFU recovery, while OnGuard2 vial adapters reduced recovery. Conclusions: This work provides an end-to-end, translationally focused characterization of a GMP-manufactured Lm cancer vaccine, including clinically actionable in-use handling constraints and device compatibility. These data define preparation and administration guardrails (notably, time-to-infusion limits for low-dose bag preparations) that can improve dose accuracy and reproducibility in clinical testing.

Authors

Institutions

Publication Details

Journal
Vaccines
Published
2026-05-21
DOI
https://doi.org/10.3390/vaccines14050461
Primary Topic
Immunotherapy and Immune Responses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-Use Stability and Device Compatibility Define Clinically Actionable Handling Limits for a GMP-Produced Attenuated Listeria monocytogenes Vaccine Expressing GUCY2C

Scott A. Waldman, Babar Bashir, Jagmohan Singh, Adam E. Snook et al.
Vaccines
Immunotherapy and Immune Responses
article

In-Use Stability and Device Compatibility Define Clinically Actionable Handling Limits for a GMP-Produced Attenuated Listeria monocytogenes Vaccine Expressing GUCY2C

Scott A. Waldman, Babar Bashir, Jagmohan Singh, Adam E. Snook, Taranjot Johar, Vannessa Scully
article en

Abstract

Background: Live-attenuated Listeria monocytogenes (Lm) vectors are a clinically validated cancer immunotherapy platform, but translation requires reproducible, clinically realistic workflows for dose preparation and infusion. For live bacterial products, in-use stability and device compatibility can drive dose variability through adsorption, settling, and device losses. Methods: We developed and GMP-manufactured an attenuated Lm vaccine expressing human GUCY2C (Lm-GUCY2C) and performed translational characterization, including construct verification and immunogenicity readouts, and defined the administration-focused in-use stability and device compatibility. Post-thaw stability was assessed in primary cryovials and during preparation and delivery from 250 mL saline infusion bags using standard clinical devices (syringes/needles, filter-free IV tubing) and OnGuard2 closed-system components. Samples were collected over 24 h at room temperature, and viable Lm-GUCY2C were quantified by CFU recovery. Results: Lm-GUCY2C remained stable in thawed cryovials for 24 h with no significant CFU loss. High-dose infusion bags (3 × 109 CFU/bag) maintained CFU recovery through 6 h, whereas low-dose bags (3 × 108 CFU/bag) exhibited significant losses beginning at 3 h, supporting a practical in-use window of up to 2 h for low-dose preparations. OnGuard2 intravenous (i.v.) connectors did not measurably affect CFU recovery, while OnGuard2 vial adapters reduced recovery. Conclusions: This work provides an end-to-end, translationally focused characterization of a GMP-manufactured Lm cancer vaccine, including clinically actionable in-use handling constraints and device compatibility. These data define preparation and administration guardrails (notably, time-to-infusion limits for low-dose bag preparations) that can improve dose accuracy and reproducibility in clinical testing.

VaccinesVol. 14(5)
Thomas Jefferson University (US), Thomas Jefferson University Hospital (US)
U.S. Department of Defense, Robert J. Kleberg, Jr. and Helen C. Kleberg Foundation, National Institutes of Health
Good health and well-being
Openalex Percentile: Top 9%
Immunotherapy and Immune Responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.