A comprehensive vulnerability assessment framework for water leakage in subway networks: case study of Beijing, China

Water leakage in metro systems poses a persistent threat to structural durability and operational safety, particularly in water-bearing environments where leakage-induced deterioration may propagate through interconnected stations. While previous studies have extensively investigated leakage mechanisms and local structural responses, limited attention has been paid to the system-level vulnerability of metro networks under leakage disturbances, particularly the lack of an integrated framework linking leakage susceptibility and network characteristics. To address this gap, this study aims to develop an integrated framework for assessing station-level vulnerability in metro networks by incorporating both network characteristics and leakage susceptibility factors. Methodologically, network properties are first quantified by integrating topological structure and passenger flow characteristics. Leakage susceptibility is then evaluated using a fuzzy comprehensive evaluation method based on field investigation data. A combined weighting approach is further employed to integrate network and leakage indicators into a unified vulnerability assessment framework. Finally, a Monte Carlo probabilistic failure model is introduced to evaluate system robustness, and station vulnerability is ranked using the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) method. The results indicate that leakage-related factors contribute dominantly to station vulnerability, accounting for approximately 62.4% of the overall weight, highlighting their critical role in metro system performance degradation. Several stations are identified as high-risk nodes due to the combined effects of unfavorable hydrogeological conditions and topological importance. The proposed framework can support infrastructure managers in prioritizing inspection scheduling, preventive maintenance, and targeted reinforcement, thereby enhancing the resilience of metro systems against leakage-induced disruptions. Future work should incorporate multi-temporal operational data and real-time monitoring information, and further validate the model using long-term maintenance records to improve its practical applicability.

Authors

Institutions

Publication Details

Journal
Smart Construction
Published
2026-05-21
DOI
https://doi.org/10.55092/sc20260009
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comprehensive vulnerability assessment framework for water leakage in subway networks: case study of Beijing, China

Sulei Zhang, Yang Xiang, Qing Xu, Pengfei Li et al.
Smart Construction
Water Systems and Optimization
article

A comprehensive vulnerability assessment framework for water leakage in subway networks: case study of Beijing, China

Sulei Zhang, Yang Xiang, Qing Xu, Pengfei Li, Yi Li, Junjie Zeng
article en

Abstract

Water leakage in metro systems poses a persistent threat to structural durability and operational safety, particularly in water-bearing environments where leakage-induced deterioration may propagate through interconnected stations. While previous studies have extensively investigated leakage mechanisms and local structural responses, limited attention has been paid to the system-level vulnerability of metro networks under leakage disturbances, particularly the lack of an integrated framework linking leakage susceptibility and network characteristics. To address this gap, this study aims to develop an integrated framework for assessing station-level vulnerability in metro networks by incorporating both network characteristics and leakage susceptibility factors. Methodologically, network properties are first quantified by integrating topological structure and passenger flow characteristics. Leakage susceptibility is then evaluated using a fuzzy comprehensive evaluation method based on field investigation data. A combined weighting approach is further employed to integrate network and leakage indicators into a unified vulnerability assessment framework. Finally, a Monte Carlo probabilistic failure model is introduced to evaluate system robustness, and station vulnerability is ranked using the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) method. The results indicate that leakage-related factors contribute dominantly to station vulnerability, accounting for approximately 62.4% of the overall weight, highlighting their critical role in metro system performance degradation. Several stations are identified as high-risk nodes due to the combined effects of unfavorable hydrogeological conditions and topological importance. The proposed framework can support infrastructure managers in prioritizing inspection scheduling, preventive maintenance, and targeted reinforcement, thereby enhancing the resilience of metro systems against leakage-induced disruptions. Future work should incorporate multi-temporal operational data and real-time monitoring information, and further validate the model using long-term maintenance records to improve its practical applicability.

Smart Construction
University of South Australia (AU), Beijing University of Technology (CN), Qingdao University of Technology (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 9%
Water Systems and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.