Clinical validation of SonoCurve, a machine-learning sound-based uroflowmetry algorithm, in adult men with lower urinary tract symptoms

Objectives To validate the clinical performance of SonoCurve, a machine-learning algorithm that provides uroflowmetry metrics from the sound of the urinary void, in adult men with lower urinary tract symptoms (LUTS). Design Prospective within-person equivalence validation study. Setting Single-centre specialist urology clinic. Participants Adult men undergoing uroflowmetry as part of LUTS assessment (September 2024–February 2025). Intervention Simultaneous conventional uroflowmetry and smartphone audio recording of the urinary stream. Recordings were processed using SonoCurve to calculate flow parameters from sound spectrograms. Outcome measures Primary: equivalence of maximum flow rate (Qmax) versus conventional uroflowmetry within a ±2 mL/s margin. The mean absolute difference (MAD) described pairwise variability. Secondary: agreement analyses for Qmax, average flow rate (Qave), voided volume (VV) and voiding time (VT), and curve-shape similarity. Results 62 men (median age 55 years, range 19–85) were included. SonoCurve achieved equivalence for Qmax (mean difference −1.19 mL/s; SD 3.11; 90% CI −1.85 to −0.53 mL/s; p=0.022). MAD was 2.69 mL/s. Lin’s concordance correlation coefficients (95% CI) were: Qmax 0.81 (0.71–0.88), Qave 0.90 (0.85–0.93), VV 0.95 (0.92–0.97) and VT 0.97 (0.95–0.98). Bland-Altman plots showed minimal bias and narrow limits of agreement. Flow-curve similarity was high (root mean square error (RMSE) 2.88±1.23 mL/s, dynamic time-warping (DTW) RMSE 0.84±0.49 mL/s). No adverse events occurred. Conclusions SonoCurve accurately measured uroflowmetry parameters from voiding sound in men with LUTS, achieving statistical equivalence for Qmax and excellent concordance across all secondary measures. Findings support use of SonoCurve as a precise, accessible alternative to clinic-based uroflowmetry and highlight its potential role in remote male LUTS assessment.

Authors

Institutions

Publication Details

Journal
BMJ Innovations
Published
2026-05-21
DOI
https://doi.org/10.1136/bmjinnov-2025-001511
Primary Topic
Urinary Bladder and Prostate Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical validation of SonoCurve, a machine-learning sound-based uroflowmetry algorithm, in adult men with lower urinary tract symptoms

Rajan Kumar Sinha, W.D. Maynard, C. Rynne, Christopher C Khoo
BMJ Innovations
Urinary Bladder and Prostate Research
article

Clinical validation of SonoCurve, a machine-learning sound-based uroflowmetry algorithm, in adult men with lower urinary tract symptoms

Rajan Kumar Sinha, W.D. Maynard, C. Rynne, Christopher C Khoo
article en

Abstract

Objectives To validate the clinical performance of SonoCurve, a machine-learning algorithm that provides uroflowmetry metrics from the sound of the urinary void, in adult men with lower urinary tract symptoms (LUTS). Design Prospective within-person equivalence validation study. Setting Single-centre specialist urology clinic. Participants Adult men undergoing uroflowmetry as part of LUTS assessment (September 2024–February 2025). Intervention Simultaneous conventional uroflowmetry and smartphone audio recording of the urinary stream. Recordings were processed using SonoCurve to calculate flow parameters from sound spectrograms. Outcome measures Primary: equivalence of maximum flow rate (Qmax) versus conventional uroflowmetry within a ±2 mL/s margin. The mean absolute difference (MAD) described pairwise variability. Secondary: agreement analyses for Qmax, average flow rate (Qave), voided volume (VV) and voiding time (VT), and curve-shape similarity. Results 62 men (median age 55 years, range 19–85) were included. SonoCurve achieved equivalence for Qmax (mean difference −1.19 mL/s; SD 3.11; 90% CI −1.85 to −0.53 mL/s; p=0.022). MAD was 2.69 mL/s. Lin’s concordance correlation coefficients (95% CI) were: Qmax 0.81 (0.71–0.88), Qave 0.90 (0.85–0.93), VV 0.95 (0.92–0.97) and VT 0.97 (0.95–0.98). Bland-Altman plots showed minimal bias and narrow limits of agreement. Flow-curve similarity was high (root mean square error (RMSE) 2.88±1.23 mL/s, dynamic time-warping (DTW) RMSE 0.84±0.49 mL/s). No adverse events occurred. Conclusions SonoCurve accurately measured uroflowmetry parameters from voiding sound in men with LUTS, achieving statistical equivalence for Qmax and excellent concordance across all secondary measures. Findings support use of SonoCurve as a precise, accessible alternative to clinic-based uroflowmetry and highlight its potential role in remote male LUTS assessment.

BMJ Innovations
King's College London (GB), Wexham Park Hospital (GB), Frimley Health NHS Foundation Trust (GB), London Institute for Mathematical Sciences (GB), Tilka Manjhi Bhagalpur University (IN)
Quality Education
Openalex Percentile: Top 5%
Urinary Bladder and Prostate Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.