Electrical Resistance Activation of Embedded Fe-SMA Rebars in Pre-Cracked UHPFRC Beams: Internal Temperature Evolution and Calibrated Electro-Thermal Simulation

Iron-based shape memory alloy (Fe–SMA) rebars can generate internal prestress in cement-based members after restrained thermal activation; however, the temperature actually reached by embedded rebars in cracked UHPFRC is difficult to infer from exposed bar segments. This study investigates electrical resistance activation of 4% prestrained Fe–SMA rebars embedded in pre-cracked UHPFRC beams and clarifies the activation-control problem by combining thermocouple measurements with a calibrated two-dimensional electro-thermal simulator. Twelve beams (150 × 150 × 600 mm) containing either Dramix 3D or Dramix 4D hooked steel fibers were first loaded in three-point bending to a mid-span displacement of 4 mm. The 4D series reached a 9.47% higher average pre-cracking load, confirming that fiber geometry modified the cracked state before heating. During activation, the exposed rebar segment reached 200 °C after approximately 77 s, whereas the embedded working segment reached the same target only after approximately 213 s; at that moment, the exposed segment was already close to 350 °C. The calibrated simulator reproduced the target activation time with an error of approximately 3 s and visualized the localized heat transfer from Fe–SMA to UHPFRC. The results demonstrate that activation control based only on exposed-bar temperature may cause under-activation of the embedded reinforcement, and that direct internal temperature monitoring is required for reliable Fe–SMA activation in cracked UHPFRC members.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-05-21
DOI
https://doi.org/10.3390/ma19102163
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical Resistance Activation of Embedded Fe-SMA Rebars in Pre-Cracked UHPFRC Beams: Internal Temperature Evolution and Calibrated Electro-Thermal Simulation

Arkadiusz Dobrzycki, Alireza Tabrizikahou, Grzegorz Trzmiel, Karol Nowak et al.
Materials
Concrete Corrosion and Durability
article

Electrical Resistance Activation of Embedded Fe-SMA Rebars in Pre-Cracked UHPFRC Beams: Internal Temperature Evolution and Calibrated Electro-Thermal Simulation

Arkadiusz Dobrzycki, Alireza Tabrizikahou, Grzegorz Trzmiel, Karol Nowak, Jan Białasik, Krzysztof Lehmann
article en

Abstract

Iron-based shape memory alloy (Fe–SMA) rebars can generate internal prestress in cement-based members after restrained thermal activation; however, the temperature actually reached by embedded rebars in cracked UHPFRC is difficult to infer from exposed bar segments. This study investigates electrical resistance activation of 4% prestrained Fe–SMA rebars embedded in pre-cracked UHPFRC beams and clarifies the activation-control problem by combining thermocouple measurements with a calibrated two-dimensional electro-thermal simulator. Twelve beams (150 × 150 × 600 mm) containing either Dramix 3D or Dramix 4D hooked steel fibers were first loaded in three-point bending to a mid-span displacement of 4 mm. The 4D series reached a 9.47% higher average pre-cracking load, confirming that fiber geometry modified the cracked state before heating. During activation, the exposed rebar segment reached 200 °C after approximately 77 s, whereas the embedded working segment reached the same target only after approximately 213 s; at that moment, the exposed segment was already close to 350 °C. The calibrated simulator reproduced the target activation time with an error of approximately 3 s and visualized the localized heat transfer from Fe–SMA to UHPFRC. The results demonstrate that activation control based only on exposed-bar temperature may cause under-activation of the embedded reinforcement, and that direct internal temperature monitoring is required for reliable Fe–SMA activation in cracked UHPFRC members.

MaterialsVol. 19(10)
Poznań University of Technology (PL)
Politechnika Poznańska, Narodowe Centrum Nauki
Openalex Percentile: Top 9%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.