Sustainable high-throughput microwell spectrophotometric methods for avapritinib quality control via charge-transfer complexation

Avapritinib (AVA) is a breakthrough targeted therapy as the first potent inhibitor approved for gastrointestinal stromal tumors (GIST) with PDGFRA D842V mutations. It lacks convenient analytical methods for routine quality control. This study addresses this gap by developing and validating two novel, green, high-throughput microwell spectrophotometric methods (MW-SPMs) for AVA quantification in pharmaceutical tablets-representing the first employment of charge-transfer complexation for AVA analysis. The methods exploit rapid charge-transfer complex (CTC) formation between AVA (electron donor) and two π-acceptors: 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) and chloranilic acid (CLA). The reactions, conducted in 96-well plates using only 200 µL total volume, yielded stable colored complexes with absorption maxima at 460 nm and 520 nm for the reactions with DDQ and CLA, respectively. Following ICH-compliant optimization and validation, both methods demonstrate excellent linearity (3.13-100 µg/well for DDQ; 6.25-100 µg/well for CLA), precision (RSD ≤ 1.8%), and accuracy (recoveries: 98.0-101.7%). Job's method confirmed 1:1 stoichiometry, while density functional theory (DFT) uniquely revealed the molecular basis for the stronger binding affinity of DDQ over CLA through dominant π-π stacking and hydrogen-bonding interactions, demonstrating how computational analysis can guide reagent selection in analytical method development. A comprehensive multi-metric sustainability assessment-utilizing ten tools including AES, AGREE, BAGI, RGB, and RAPI-confirmed the methods' excellent greenness (e.g., AES score = 90), superior practicality, and robust analytical performance, achieving a high White Index of 94.2%. With a substantially higher throughput of ~ 500 samples/hour and minimal solvent consumption (200µL/well), the proposed MW-SPMs offers a rapid, sustainable, and cost-effective alternative to conventional chromatographic and spectrofluorimetric techniques for routine pharmaceutical analysis, aligning with multiple United Nations Sustainable Development Goals.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-21
DOI
https://doi.org/10.1038/s41598-026-51872-6
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sustainable high-throughput microwell spectrophotometric methods for avapritinib quality control via charge-transfer complexation

Antonio Frontera, Waleed Alahmad, Ibrahim Ali Darwish, Awadh M. Ali et al.
Scientific Reports
Advanced Biosensing Techniques and Applications
article

Sustainable high-throughput microwell spectrophotometric methods for avapritinib quality control via charge-transfer complexation

Antonio Frontera, Waleed Alahmad, Ibrahim Ali Darwish, Awadh M. Ali, Weam M. Othman, Mohammed S. Alsalhi
article en

Abstract

Avapritinib (AVA) is a breakthrough targeted therapy as the first potent inhibitor approved for gastrointestinal stromal tumors (GIST) with PDGFRA D842V mutations. It lacks convenient analytical methods for routine quality control. This study addresses this gap by developing and validating two novel, green, high-throughput microwell spectrophotometric methods (MW-SPMs) for AVA quantification in pharmaceutical tablets-representing the first employment of charge-transfer complexation for AVA analysis. The methods exploit rapid charge-transfer complex (CTC) formation between AVA (electron donor) and two π-acceptors: 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) and chloranilic acid (CLA). The reactions, conducted in 96-well plates using only 200 µL total volume, yielded stable colored complexes with absorption maxima at 460 nm and 520 nm for the reactions with DDQ and CLA, respectively. Following ICH-compliant optimization and validation, both methods demonstrate excellent linearity (3.13-100 µg/well for DDQ; 6.25-100 µg/well for CLA), precision (RSD ≤ 1.8%), and accuracy (recoveries: 98.0-101.7%). Job's method confirmed 1:1 stoichiometry, while density functional theory (DFT) uniquely revealed the molecular basis for the stronger binding affinity of DDQ over CLA through dominant π-π stacking and hydrogen-bonding interactions, demonstrating how computational analysis can guide reagent selection in analytical method development. A comprehensive multi-metric sustainability assessment-utilizing ten tools including AES, AGREE, BAGI, RGB, and RAPI-confirmed the methods' excellent greenness (e.g., AES score = 90), superior practicality, and robust analytical performance, achieving a high White Index of 94.2%. With a substantially higher throughput of ~ 500 samples/hour and minimal solvent consumption (200µL/well), the proposed MW-SPMs offers a rapid, sustainable, and cost-effective alternative to conventional chromatographic and spectrofluorimetric techniques for routine pharmaceutical analysis, aligning with multiple United Nations Sustainable Development Goals.

Scientific ReportsVol. 16(1)
Demos (US), Misr University for Science and Technology (EG), Chulalongkorn University (TH), King Saud University (SA), Universitat de les Illes Balears (ES)
Industry, innovation and infrastructure
Openalex Percentile: Top 9%
Advanced Biosensing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.