Automated ultrasound with AI for osteophyte grading in hand osteoarthritis: comparison with expert rheumatologist assessment

BACKGROUND: The objective of this study was to characterise the agreement of the CE-certified automated robotic ultrasound system ARTHUR v.2.0, combined with the AI model DIANA v.2.0, for grading osteophytes in hand osteoarthritis (OA), using expert rheumatologist assessment as the reference standard. METHODS: Thirty patients with hand OA underwent ultrasound of MCP, PIP, and DIP joints with ARTHUR v.2.0 and subsequently by an expert rheumatologist. Osteophytes were graded (0-3) using the OMERACT system. Agreement was assessed using weighted Cohen's kappa (κ), Percent Exact Agreement (PEA), Percent Close Agreement (PCA), sensitivity, and specificity. Comparisons were made against both the primary rheumatologist and an independent blinded external assessor (EA). RESULTS: ARTHUR v.2.0 successfully scanned 703/840 joints (83.7%), with lower success in DIP joints. Agreement between ARTHUR+DIANA and the rheumatologist showed κ = 0.49, PEA 53.7%, and PCA 90.7%. Compared to the EA, the automated system showed κ = 0.46 and PCA 90.5%. Agreement between the rheumatologist and EA showed κ = 0.67 and PCA 97.5%. Binary agreement for disease presence (≥ Grade 2) for the automated system was 81.6% compared to the rheumatologist, although sensitivity was limited (36.5%). CONCLUSIONS: ARTHUR v.2.0 combined with DIANA v.2.0 achieved binary agreement comparable to expert-expert comparisons, although with limited sensitivity, and moderate agreement on the full 0-3 OMERACT scale. A decomposition analysis indicated that acquisition-related variability contributed substantially to the overall discrepancy. Refinement of AI threshold calibration and distal joint acquisition, and evaluation in larger and more diverse cohorts, is warranted to further improve sensitivity for osteophyte detection.

Authors

Institutions

Publication Details

Journal
BMC Rheumatology
Published
2026-05-21
DOI
https://doi.org/10.1186/s41927-026-00654-8
Primary Topic
Osteoarthritis Treatment and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated ultrasound with AI for osteophyte grading in hand osteoarthritis: comparison with expert rheumatologist assessment

Mads Ammitzbøll‐Danielsen, Bill Aplin Frederiksen, Søren Andreas Just, Lene Terslev et al.
BMC Rheumatology
Osteoarthritis Treatment and Mechanisms
article

Automated ultrasound with AI for osteophyte grading in hand osteoarthritis: comparison with expert rheumatologist assessment

Mads Ammitzbøll‐Danielsen, Bill Aplin Frederiksen, Søren Andreas Just, Lene Terslev, Thiusius Rajeeth Savarimuthu, Anders Bossel Holst Weber, Hilde Berner Hammer
article en

Abstract

BACKGROUND: The objective of this study was to characterise the agreement of the CE-certified automated robotic ultrasound system ARTHUR v.2.0, combined with the AI model DIANA v.2.0, for grading osteophytes in hand osteoarthritis (OA), using expert rheumatologist assessment as the reference standard. METHODS: Thirty patients with hand OA underwent ultrasound of MCP, PIP, and DIP joints with ARTHUR v.2.0 and subsequently by an expert rheumatologist. Osteophytes were graded (0-3) using the OMERACT system. Agreement was assessed using weighted Cohen's kappa (κ), Percent Exact Agreement (PEA), Percent Close Agreement (PCA), sensitivity, and specificity. Comparisons were made against both the primary rheumatologist and an independent blinded external assessor (EA). RESULTS: ARTHUR v.2.0 successfully scanned 703/840 joints (83.7%), with lower success in DIP joints. Agreement between ARTHUR+DIANA and the rheumatologist showed κ = 0.49, PEA 53.7%, and PCA 90.7%. Compared to the EA, the automated system showed κ = 0.46 and PCA 90.5%. Agreement between the rheumatologist and EA showed κ = 0.67 and PCA 97.5%. Binary agreement for disease presence (≥ Grade 2) for the automated system was 81.6% compared to the rheumatologist, although sensitivity was limited (36.5%). CONCLUSIONS: ARTHUR v.2.0 combined with DIANA v.2.0 achieved binary agreement comparable to expert-expert comparisons, although with limited sensitivity, and moderate agreement on the full 0-3 OMERACT scale. A decomposition analysis indicated that acquisition-related variability contributed substantially to the overall discrepancy. Refinement of AI threshold calibration and distal joint acquisition, and evaluation in larger and more diverse cohorts, is warranted to further improve sensitivity for osteophyte detection.

BMC Rheumatology
University of Southern Denmark (DK), Maersk (Denmark) (DK), University of Oslo (NO), Glostrup Hospital (DK), Rigshospitalet (DK), Directorate-General for Justice and Consumers (BE), Diakonhjemmet Hospital (NO), Svendborg Sygehus (DK)
Syddansk Universitet
Openalex Percentile: Top 5%
Osteoarthritis Treatment and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.