Application of Simultaneous Chemical and Electrochemical Oxidation Treatment (O3–EO) in River Water and Its Pollutant and Phytotoxicity Evaluation

Continuous discharges from diverse industrial activities have severely degraded the water quality of the Lerma River, turning it into a major environmental, social, and public health concern. Conventional wastewater treatment processes are often insufficient for eliminating persistent and refractory organic pollutants; therefore, the implementation of advanced oxidation processes (AOPs) is increasingly required to restore water quality. In this context, the present study systematically evaluated the individual and combined effects of ozonation and electrochemical oxidation using boron-doped diamond (BDD) electrodes for the treatment of contaminated river water. Ozonation alone achieved an 89% reduction in turbidity and a 19% decrease in total organic carbon (TOC), while electrochemical oxidation reduced turbidity by 82% and TOC by 57%. Remarkably, the simultaneous application of both treatments resulted in a 98% reduction in turbidity and an 80% decrease in TOC, clearly demonstrating a strong synergistic effect. Regarding true color at 436 nm, associated with yellow chromophore compounds, removal efficiencies of 98.9%, 94.7%, and 67.3% were obtained for the combined process, electrochemical oxidation, and ozonation, respectively. Phytotoxicity tests with Lactuca sativa seeds showed no statistically significant difference in toxicity in water treated with the O3–EO System compared to raw water. These results highlight, for the first time under real river water conditions, the superior performance of the integrated O3–EO system as an effective strategy for the intensified degradation and partial mineralization of persistent organic contaminants, thereby underscoring its strong potential for advanced remediation of heavily polluted surface waters.

Authors

Institutions

Publication Details

Journal
Catalysts
Published
2026-05-21
DOI
https://doi.org/10.3390/catal16050486
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Simultaneous Chemical and Electrochemical Oxidation Treatment (O3–EO) in River Water and Its Pollutant and Phytotoxicity Evaluation

Cinthya Pamela Del Río Galván, Manuel Palomar‐Pardavé, Gabriela Roa-Morales, Carlos Barrera-Díaz et al.
Catalysts
Advanced oxidation water treatment
article

Application of Simultaneous Chemical and Electrochemical Oxidation Treatment (O3–EO) in River Water and Its Pollutant and Phytotoxicity Evaluation

Cinthya Pamela Del Río Galván, Manuel Palomar‐Pardavé, Gabriela Roa-Morales, Carlos Barrera-Díaz, Ariana de la Cruz-Hernández, Lilia Tapia-López
article en

Abstract

Continuous discharges from diverse industrial activities have severely degraded the water quality of the Lerma River, turning it into a major environmental, social, and public health concern. Conventional wastewater treatment processes are often insufficient for eliminating persistent and refractory organic pollutants; therefore, the implementation of advanced oxidation processes (AOPs) is increasingly required to restore water quality. In this context, the present study systematically evaluated the individual and combined effects of ozonation and electrochemical oxidation using boron-doped diamond (BDD) electrodes for the treatment of contaminated river water. Ozonation alone achieved an 89% reduction in turbidity and a 19% decrease in total organic carbon (TOC), while electrochemical oxidation reduced turbidity by 82% and TOC by 57%. Remarkably, the simultaneous application of both treatments resulted in a 98% reduction in turbidity and an 80% decrease in TOC, clearly demonstrating a strong synergistic effect. Regarding true color at 436 nm, associated with yellow chromophore compounds, removal efficiencies of 98.9%, 94.7%, and 67.3% were obtained for the combined process, electrochemical oxidation, and ozonation, respectively. Phytotoxicity tests with Lactuca sativa seeds showed no statistically significant difference in toxicity in water treated with the O3–EO System compared to raw water. These results highlight, for the first time under real river water conditions, the superior performance of the integrated O3–EO system as an effective strategy for the intensified degradation and partial mineralization of persistent organic contaminants, thereby underscoring its strong potential for advanced remediation of heavily polluted surface waters.

CatalystsVol. 16(5)
Universidad Autónoma del Estado de México (MX), Universidad Autónoma Metropolitana (MX), Universidad Politécnica de Zacatecas (MX), Universidad Autónoma de Zacatecas "Francisco García Salinas" (MX), Instituto Politécnico Nacional (MX)
Clean water and sanitation
Openalex Percentile: Top 11%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.