Objective-function-guided automated VMAT planning reduces OAR dose, low-dose exposure, and inter-planner variability in breast radiotherapy

This study presents and evaluates an automated volumetric modulated arc therapy (VMAT) planning framework for breast cancer based on objective function value (OFV)-guided optimization. The primary objective is to systematically improve organ-at-risk sparing through automated and reproducible optimization of planning constraints while maintaining clinically acceptable target coverage. An OFV-guided optimization workflow was empirically developed using a separate sensitivity dataset and subsequently evaluated in 20 clinical breast cancer patients (13 left-sided, 7 right-sided). The automated Python-based framework iteratively adapts MaxEUD constraints during optimization until dose metrics converge, without manual intervention. Automatically generated plans were compared to clinically delivered VMAT plans using target coverage, dose-volume metrics, and monitor units as a surrogate for delivery efficiency. The automated approach consistently achieved significant reductions in mean organ doses and low-dose volumes (e.g., [Formula: see text], [Formula: see text]) while preserving PTV coverage. Mean heart dose decreased from [Formula: see text] Gy to [Formula: see text] Gy for left-sided cases and from [Formula: see text] Gy to [Formula: see text] Gy for right-sided cases ([Formula: see text]). Significant dose reductions were also observed for the ipsilateral lung, contralateral lung, and contralateral breast, accompanied by a 16.9 % reduction in monitor units ([Formula: see text]) and reduced inter-patient variability. In contrast, no statistically significant difference was observed for lung [Formula: see text]. In conclusion, OFV-guided VMAT optimization enables reproducible and systematic improvement of organ-at-risk sparing in breast radiotherapy. By reducing organ doses, low-dose burden, monitor units, and inter-patient variability without compromising target coverage, the proposed framework could provide a robust and standardized baseline for clinical VMAT planning and a consistent foundation for future data-driven and machine-learning-based optimization approaches.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-21
DOI
https://doi.org/10.1038/s41598-026-52616-2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Objective-function-guided automated VMAT planning reduces OAR dose, low-dose exposure, and inter-planner variability in breast radiotherapy

Hannes Rennau, Guido Hildebrandt
Scientific Reports
Advanced Radiotherapy Techniques
article

Objective-function-guided automated VMAT planning reduces OAR dose, low-dose exposure, and inter-planner variability in breast radiotherapy

Hannes Rennau, Guido Hildebrandt
article en

Abstract

This study presents and evaluates an automated volumetric modulated arc therapy (VMAT) planning framework for breast cancer based on objective function value (OFV)-guided optimization. The primary objective is to systematically improve organ-at-risk sparing through automated and reproducible optimization of planning constraints while maintaining clinically acceptable target coverage. An OFV-guided optimization workflow was empirically developed using a separate sensitivity dataset and subsequently evaluated in 20 clinical breast cancer patients (13 left-sided, 7 right-sided). The automated Python-based framework iteratively adapts MaxEUD constraints during optimization until dose metrics converge, without manual intervention. Automatically generated plans were compared to clinically delivered VMAT plans using target coverage, dose-volume metrics, and monitor units as a surrogate for delivery efficiency. The automated approach consistently achieved significant reductions in mean organ doses and low-dose volumes (e.g., [Formula: see text], [Formula: see text]) while preserving PTV coverage. Mean heart dose decreased from [Formula: see text] Gy to [Formula: see text] Gy for left-sided cases and from [Formula: see text] Gy to [Formula: see text] Gy for right-sided cases ([Formula: see text]). Significant dose reductions were also observed for the ipsilateral lung, contralateral lung, and contralateral breast, accompanied by a 16.9 % reduction in monitor units ([Formula: see text]) and reduced inter-patient variability. In contrast, no statistically significant difference was observed for lung [Formula: see text]. In conclusion, OFV-guided VMAT optimization enables reproducible and systematic improvement of organ-at-risk sparing in breast radiotherapy. By reducing organ doses, low-dose burden, monitor units, and inter-patient variability without compromising target coverage, the proposed framework could provide a robust and standardized baseline for clinical VMAT planning and a consistent foundation for future data-driven and machine-learning-based optimization approaches.

Scientific ReportsVol. 16(1)
University of Rostock (DE)
Good health and well-being
Openalex Percentile: Top 6%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.